Blue-White industries Chem-Feed C-1700N Скачать руководство пользователя страница 8

5.0

How To Operate The C-1700N

5.1

Adjusting the Pump Output- Standard models (fig. 5.1)  - 

The C-1700N flow rate(s) can be adjusted 

within a range of 5% -100% of maximum output (20:1 turndown ratio) by means of two mechanical, 
cam type mechanisms. The mechanism adjusts the pump’s stroke length to an infinite number of settings 
within the flow range. Because the pump’s output is reduced by increasing the pressure of the system 
being injected into, the amount of suction lift, and the viscosity of the fluid being injected, the pump 
must be over-sized to allow for these factors.  Sizing the pump to allow adjustment within the midrange 
is preferred to maintain accuracy. Consult the factory for individual pump model output curve data. 

To 

adjust the pump’s output

:

1. With the pump running, loosen the set screw.

2. Turn the adjustment knob to the desired setting.

3. Re-tighten the set screw.

C-1700N

Page 8

5.2

Adjusting the  Pump Output - DELUXE Models (fig. 5.2)

In addition to the two cam type mechanism adjustments (section 5.1), the pump output of the C-1700N 
deluxe unit equipped with an optional electronic cycle timer board can also be fine tuned by adjusting 
the timer adjustment knob. The total-time cycle is factory preset and is not user adjustable. The on-time 
cycle is adjustable from 5% to 100% of the total cycle time. Example: If the total-time cycle is 5 seconds 
and the on-time cycle is adjusted for 20 percent, the pump will run for 1 second and turn off for 4 
seconds (5 second total cycle). This cycle is repeated until either the cycle time is changed or the input 
power is disconnected from the pump.

Note: When the input power is disconnected from the C-1700N, the unit will maintain the last 
adjusted settings. When power is restored to the pump, the C-1700N will begin to pump using the 
last time cycle setting.

FIG. 5.2

To 

adjust the

 

On-Time :

Turn the timer adjustment knob located on the 
junction box cover.

Clockwise increases the time on.

FIG. 5.1

     Adjustment Knobs
(Cam Type Mechanism)

    Cycle Timer 
Adjustment Knob

Junction Box

MAX

MIN

1

2

3

4

5

6

7

8

9

MAX

MIN

1

2

3

4

5

6

7

8

9

ADJUST WHILE

RUNNING

LOOSEN SCREW

TURN KNOB

RE-TIGHTEN SCREW

Содержание Chem-Feed C-1700N

Страница 1: ...gton Beach CA 92649 www Blue White com MODEL C 1700N Positive Displacement Injector Pump Operating Manual PT SARANA PRIMA ENGUNA Jl Gunung Sahari Raya 84 C Jakarta 10610 Phone 021 420 0045 FAX 021 420...

Страница 2: ...tering pump The C 1700N is designed to inject chemicals into piping systems The pump has been tested by NSF International for use with 12 Sodium Hypochlorite All models are equipped with two top mount...

Страница 3: ...is designed to withstand outdoor conditions a cool dry well ventilated location is recommended Install the pump where it can be easily serviced Mount the pump to a secure surface or wall using the en...

Страница 4: ...lamp Wall Mount Chemical 2 NPT Injector Discharge Tube Suction Tube Suction Tube Risk of chemical overdose Be certain the pump does not overdose chemical during backwash and periods of no flow in the...

Страница 5: ...in the junction box FIG 4 4 WIRING DIAGRAM STANDARD MODELS AC MOTOR INPUT VOLTAGE 115V 60Hz HOT LEADWIRE NEUTRAL LEADWIRE GROUND LEADWIRE 230V 60Hz BLUE or YELLOW BLUE BROWN RED GREEN GREEN GREEN MOT...

Страница 6: ...itting of the pump head see fig 4 6 Remove the tube nut Push the opaque outlet discharge tubing onto the compression barb of the fitting Use the tube nut to secure the tube Hand tighten only Trim the...

Страница 7: ...Teflon thread sealing tape on the pipe threads Push the opaque outlet discharge tubing onto the compression barb of the Injection Check valve fitting Use the tube nut to secure the tube Hand tighten...

Страница 8: ...cam type mechanism adjustments section 5 1 the pump output of the C 1700N deluxe unit equipped with an optional electronic cycle timer board can also be fine tuned by adjusting the timer adjustment kn...

Страница 9: ...ect all components for signs of leaking swelling cracking discoloration or corrosion Replace worn or damaged components immediately Cracking crazing discoloration and the like during the first week of...

Страница 10: ...C 1700N Replacement Parts Drawing Page 10 45 42 44 43 46 47 48 49 50 48 51 52 53 54 12 17 18 20 21 22 23 26 27 29 37 36 38 39 41 40 25 24 13 10 11 15 14 16 55 9 2 1 4 3 6 8 7 28 19 30 31 32 33 5 34 35...

Страница 11: ...asket Top Cover 1 28 90004 005 Bearing Top Cover 1 29 70000 131 Drive Cam S A 1 125 1 70000 133 Drive Cam S A 2 055 1 70000 132 Drive Cam S A 3 187 1 70000 722 Drive Cam S A 4 100 1 30 90011 014 Space...

Страница 12: ...tors they are meant to destroy bacteria and algae contamination before it s removal by filtration Acid and soda injectors are used for PH control balance Blue White injectors are factory tested with w...

Отзывы: