5.3 Measuring the Pump’s Output - Volumetric Test.

This volumetric test will take into account individual installation factors such 
as line pressure, fluid viscosity, suction lift, etc. This test is the most accurate 
for measuring the injector’s output in an individual installation.

1. Be sure the Injection Fitting and Footvalve/Strainer is clean and working 
properly.

2. With the injector installed under normal operating conditions, place the 
Footvalve/Strainer in a large graduated cylinder.

3. Fill the graduated cylinder with the solution to be injected and run the 
injector until all air is removed from the suction line and the solution enters 
the discharge tubing.

4. Refill the graduated cylinder, if necessary, and with the Footvalve com-
pletely submerged in the solution, note the amount of solution in the graduated 
cylinder.

5. Run the injector for a measured amount of time and note the amount of fluid 
injected. A longer testing time will produce more accurate results.

6.0

How to Maintain the C-1500N

6.1

Routine Inspection and Maintenance

The C-1500N requires very little maintenance.  However, the pump and all 
accessories should be checked regularly. This is especially important when 
pumping chemicals.  Inspect all components for signs of leaking, swelling, 
cracking, discoloration or corrosion.  Replace worn or damaged components 
immediately. Cracking, crazing, discoloration and the like during the first week 
of operation are signs of severe chemical attack.  If this occurs, immediately 
remove the chemical from the pump.  Determine which parts are being attacked 
and replace them with parts that have been manufactured using more suitable 
materials.  The manufacturer does not assume responsibility for damage to the 
pump that has been caused by chemical attack.

6.2

How to Clean the C-1500N

The C-1500N will require occasional cleaning, especially the Injection fitting, 
the Footvalve/Strainer, and the pump head valves.  The frequency will depend 
on the type and severity of service..

]

When changing the diaphragm, the pump head chamber  and pump head cover 

should be wiped free of any dirt and debris.

]

Periodically clean the injection/check valve assembly, especially when injecting 

fluids that calcify such as sodium hypochlorite.  These lime deposits and other 
build ups can clog the fitting, increase the back pressure and interfere with the 
check valve operation. See section 4.3.4.  Fig. 4.8.

]

Periodically clean the suction strainer.  Fig.4.7

]

Periodically inspect the air vents located under the motor compartment and under 

the pump head.  Clean if necessary.

C-1500N

Page 9

Proper eye and skin protection must be worn 
when installing and servicing the pump.

!

CAUTION

Содержание CHEM-FEED C-1500N

Страница 1: ...M A Y B E U N D E R H I G H P R E S S U R E U S E C A R E T O P R O T E C T Y O U R S E L F W H E N D I S C O N N E C T I N G C A U T I O N A D J U S T W H I L E R U N N I N G M I N 1 2 3 4 5 6 7 8 9...

Страница 2: ...e equipped with a top mounted mechanical flow rate adjustment knob Optional on off cycling timers are available The pump has been tested by NSF International for use with 12 Sodium Hypochlorite CAUTIO...

Страница 3: ...is designed to withstand outdoor conditions a cool dry well ventilated location is recommended Install the pump where it can be easily serviced Mount the pump to a secure surface or wall using the en...

Страница 4: ...e vertical Chemical Container NPT Injector C 1500N 4 1 2 9 1 16 5 3 4 FIG 4 0 DIMENSIONAL DRAWING FIG 4 1 INJECTOR WALL MOUNTING 10 Self Tap 2 X Wall Mount Bracket C 1500N Page 4 Risk of chemical over...

Страница 5: ...in the junction box FIG 4 4 WIRING DIAGRAM STANDARD MODELS AC MOTOR INPUT VOLTAGE 115V 60Hz HOT LEADWIRE NEUTRAL LEADWIRE GROUND LEADWIRE 230V 60Hz BLUE or YELLOW BLUE BROWN RED GREEN GREEN GREEN MOT...

Страница 6: ...ubing Locate the outlet fitting of the pump head see fig 4 6 Remove the tube nut Push the opaque outlet discharge tubing onto the compression barb of the fitting Use the tube nut to secure the tube Ha...

Страница 7: ...ectly into the tee fitting Do not install the fitting into a pipe stud and then into the tee The solution must inject directly into the flow stream Use Teflon thread sealing tape on the pipe threads P...

Страница 8: ...9 LOOSEN THE LOCK SCREW TURN KNOB TO DESIRED SETTING RE TIGHTEN THE LOCK SCREW 5 2 Adjusting the Pump Output DELUXE Models fig 5 2 In addition to the cam type mechanism adjustment section 5 1 the pum...

Страница 9: ...nts for signs of leaking swelling cracking discoloration or corrosion Replace worn or damaged components immediately Cracking crazing discoloration and the like during the first week of operation are...

Страница 10: ...IL E R U N N IN G D IS C H A R G E L IN E S M A Y B E U N D E R H IG H P R E S S U R E U S E C A R E T O P R O T E C T Y O U R S E L F W H E N D IS C O N N E C T IN G M I N 1 2 3 4 5 6 7 8 9 LO O S E...

Страница 11: ...n 2 71000 226 Adapter S A Bullet 25T EP 2 71000 227 Adapter S A Bullet 25T Silicon 2 14 71000 195 Cartridge Bullet Valve S A Double Ball 2 15 90002 146 P Head Noir Molded P P 1 16 76000 168 Tubing D C...

Страница 12: ...220V50Hz Standard Brown Black 1 71000 020 Stator S A 220V50Hz Thermal Brown Yellow 1 70000 020 Stator S A 230V60Hz Standard Red Black 1 70000 021 Stator S A 230V60Hz Thermal Red Yellow 1 70000 072 Sta...

Страница 13: ......

Страница 14: ...pack the pump to be repaired include the foot strainer and injection check valve fitting Enclose a brief description of the problem as well as the original invoice or sales receipt showing the date o...

Отзывы: