Page 29
Flex-Pro
Note:
Contact #1 shown only. Contact #2, and
Contact #3 use the same menu items.
- Output Setup
+ Signal Output
+ Relay Output
+ Contact #1
+ Contact #2
Output - Signal
+ Contact #3
<- Esc
Hidden
Output - Assign Relay
- Output Setup
+ Signal Output Modes
+ Contact #1
+ Contact #2
+ Contact #3
<- Esc
+ Relay Output
- 4-20 mA Output
Signal @ min % Motor:
Input
mA Signal
@ Min % Motor speed
- 4-20 mA Output
Minimum % Motor:
Input
Min % Motor
for mA Signal Output
- 4-20 mA Output
Signal @ Max % Motor:
Input
mA signal
@ Max % Motor Speed
- 4-20 mA Output
Maximum % Motor:
Input
Maximum % Motor
for mA Signal output
- Relay Output
Both, TFD/FVS
FVS
4-20mA Mode
- Signal Output
4-20 mA Output
Freq. Output
Disable
- Signal Output
4-20 mA Output
Freq. Output
Disable
Done
Done
- Freq. Output
Signal @ Min % Motor:
Input
Frequency (Hz)
@ Min % Motor Speed
000
0
- Freq. Output
Minimum % Motor:
Input
Min % Motor
for Freq. output
00.0
0
- Freq. Output
Signal @ Max % Motor:
Input Frequency
(Hz)
@ Max % Motor Speed
000
1
- Freq. Output
Maximum % Motor:
Input
Maximum % Motor
for Freq. Output
00.0
1
Monitor Input
Monitor Output
Monitor Run/Fail
Manual Mode
- Output Setup
+ Signal Output Modes
+ Relay Output
+ Contact #2
+ Contact #3
<- Esc
+ Contact #1
- Contact Closure #1
Monitor Input
Monitor Output
Monitor Run/Fail
Both, TFD/FVS
Disable
TFD
Hidden
Hidden
Hidden
Hidden
Output -
Contact Closure #1
(select one)
(select one)
0
00.0
0
4.00
1
00.00
2
0.00
Pump Run/Stop
Frequency Mode
Cycle Timer Mode
Dispensing Mode
Manual Dosing
Prop. Dosing
0-10 VDC Mode
Pulse Mode
Disable
FVS
TFD
Pump Run/Stop
4-20mA Mode
Manual Mode
Frequency Mode
Cycle Timer Mode
Dispensing Mode
Manual Dosing Acive
Prop. Dosing Active
0-10 VDC Mode
Pulse Mode
Remote Active
Remote Active
Done
Done
Reverse Alarm
General Error
Reverse Alarm
General Error
+ Configuration
- Menu
+ Input Setup
+ Output Setup
<- Esc
+ Power Fail option
Description of Relay and Contact Closure Output triggers
Selection:
Contact energizes when:
Pump Run/Stop ........
Motor turning (roller assembly is rotating).
Monitor Input .... ........
Incoming analog or digital signal is not received or is out of range.
Monitor Output
.. ........Outgoing analog or digital signal not transmitted or is out of range.
Monitor Run/Fail
........Motor fails to respond to commands from the internal controller.
Both TFD/FVS
.. ........Either TFD or FVS system triggers.
FVS
........ ........ ........After the programmed delay time, pulses are not received from flow sensor.
TFD
........ ........ ........Tube failure is detected by sensors in the head.
Active Mode
...... ........The selected run mode is currently activated.
Remote Active .. ........
Energized when Remote only is activated.
Reverse Alarm.. ........
The motor revolution is reversed (turning clock-wise).
General Error.... ........
A motor overload or other internal error has occurred.
Disable
..... ........ ........Output alarm contact is disabled.
Relay Out Delay
Input Relay Delay:
Max Delay = 999.9 (s)
Press ENTER to set
0
00.0
Contact 1 Delay
Input Relay Delay:
Max Delay = 999.9 (s)
Press ENTER to set
0
00.0
5.0 Output Setup (alarm relays)