23
IF NO BUBBLES APPEAR AT ANY CONNECTION, THE CONNECTIONS
ARE SECURE.
NOTE: Whenever gas connections are joined, loosened or removed, you
must perform a complete leak test.
LIGHTING
WARNING
READ THE RULES FOR SAFE OPERATION SECTION AT THE
BEGINNING OF THIS MANUAL BEFORE PROCEEDING.
Do not attempt to operate until all the assembly is complete and the leak
checks have been performed. Please read all of the lighting instructions and
have an understanding of all the steps prior to lighting the heater.
WARNING
Be careful when attempting to manually ignite this heater. Holding in the
control knob for more than 10 seconds before igniting the gas will cause a
ball of flame upon ignition.
STEP 1
Fully open the LP cylinder valve.
Press and turn the control knob to
the HIGH position (counter-clockwise
90°). Holding down the control knob,
press the igniter button several times
until the main flame is ignited.
Wait 10 seconds after the ignition
before releasing the control knob.