Specifications
Gas Supply Requirements
- Australia
- New Zealand Only:
- United Kingdom & EU (CE)
Category:
II
2H3P
(20, 37), .
II
2H3B/P
(20, 28-30),
Flue Type:
A
1.
*
- Measure burner operating pressure at gas control valve outlet test point with burner operating at
‘High’ setting. Operating pressure is ex-factory set, through the appliance regulator and not to
be adjusted, apart from when converting between gases, if required. (Refer to ‘Gas Conversion’
section for details).
For Refrigeration Cabinet Specifications refer to Refrigeration Cabinet Installation and Operation
Manual supplied with appliance.
Natural Gas (G20)
GP513 GP514 GP516 GP518
GP513
GP514
GP516
GP518
Heat Input (nett)
10.5 kW 13.3 kW
21 kW
28.5 kW 10.5 kW 13.3 kW
21 kW
28.5 kW
Gas Rate (nett)
1.11 m
3
/hr 1.41 m
3
/hr 2.22 m
3
/hr 3.02 m
3
/hr 0.81 kg/hr 1.03 kg/hr 1.63 kg/hr 2.21 kg/hr
Supply Pressure
20 mbar
37 mbar
Burner Operating Pressure (*)
8.2 mbar 8.5 mbar
8.2 mbar
26 mbar
Gas Connection
3
/
4
” BSP Male
Propane (G31)
Natural Gas
GP513
GP514
GP516
GP518
GP513
GP514
GP516
GP518
Input Rating
(N.H.G.C.)
40 MJ/hr 53 MJ/hr 80 MJ/hr 108 MJ/hr 40 MJ/hr 53 MJ/hr 80 MJ/hr 108 MJ/hr
Supply Pressure
1.13 - 3.40 kPa
2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.90 kPa 0.85 kPa
0.90 kPa
2.6 kPa
2.5 kPa
2.6 kPa
Gas Connection
¾” BSP Male
LP Gas (Propane)
Natural Gas
GP513
GP514
GP516
GP518
GP513
GP514
GP516
GP518
Input Rating
(N.H.G.C.)
40 MJ/hr 53 MJ/hr 80 MJ/hr 108 MJ/hr 40 MJ/hr 53 MJ/hr 80 MJ/hr 108 MJ/hr
Supply Pressure
1.13 - 3.40 kPa
2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.90 kPa 0.85 kPa
0.90 kPa
2.6 kPa
2.5 kPa
2.6 kPa
Gas Connection
¾” BSP Male
LP Gas
LP Gas (G30 - G31)
GP513
GP514
GP516
GP518
Heat Input (nett)
12.0 kW 16.0 kW 24.0 kW 32.5 kW
Gas Rate (nett)
0.95 kg/hr 1.26 kg/hr 1.89 kg/hr 2.56 kg/hr
Supply Pressure
28 - 30 mbar
Burner Operating Pressure (*)
26 mbar
Gas Connection
3
/
4
” BSP Male