Gas Connection
Gas supply connection point is located 152 mm from the left hand side, 33 mm from the rear of the
appliance and 152 mm from the floor and is entered from beneath the appliance. An optional rear
connection is available.
Connection is
3
/
4
” BSP male.
Water Supply Requirements
A cold water supply must be connected to the water inlet connection (R
1
/
2
" BSP), located 50 mm from
the LH side, 556 mm from rear and 150 mm from the floor. This should be plumbed in, in accordance
with National / Local Codes covering installation.
Maximum water supply pressure 550kPa (80psi).
Tank capacity - 40 ltrs of water.
Specifications
Содержание Evolution series G47