Gas Specifications
- Australia / New Zealand Only
- CE Only:
Appliance Classification
Category:
II
2H3P
(20, 30 / 37).
Flue Type:
A
1.
*
The burner operating pressure is to be measured at the manifold test point with 2
burners operating at the ‘High’ setting. The operating pressure is ex-factory set, through the
appliance regulator and is not to be adjusted, apart from when carrying out gas conversion, if
required. (Refer to the ‘Gas Conversion’ section for details).
Gas Conversion and Specifications
Natural. Gas
LP Gas (Propane)
Open Burner
Main Burner Injectors
Ø 2.45 mm
Ø 1.50 mm
Pilot Burner ('PF' Models only)
0.30
0.20
Griddle
Main Burner
Ø 2.10 mm
Ø 1.30 mm
Pilot Burner
0.35
0.23
Operating Pressure
0.95 kPa (*)
2.6 kPa (*)
Gas Regulator Cap Screw
Supply Pressure
1.13 - 3.40 kPa
2.75 - 4.50 kPa
Burner Aeration Setting
Fully open
Fully open
Natural. Gas
(G20)
Propane
(G31)
Open Burner
Main Burner Injectors
Ø 2.30 mm
Ø 1.40 mm
Pilot Burner ('PF' Models only)
0.30
0.20
Griddle
Main Burner
Ø 2.10 mm
Ø 1.30 mm
Pilot Burner
0.35
0.23
Operating Pressure
9.5 mbar (*)
26 mbar (*)
Gas Regulator Cap Screw
Supply Pressure
20 mbar
30 - 37 mbar
Burner Aeration Setting
Fully open
Fully open
Содержание Evolution GE505
Страница 8: ...6 Dimensions Dimensions GE505 GE54 Refer to Page 8 for Cook Top Options Dimensions GE506 GE56 ...
Страница 9: ...7 Dimensions Dimensions GE508 GE58 Refer to Page 8 for Cook Top Options ...
Страница 25: ...23 Wiring Schematic Static Ovens GE505 GE506 GE508 Series ...
Страница 26: ...24 Wiring Schematic Convection Ovens GE54 GE56 GE58 Series ...
Страница 27: ...25 Wiring Schematics Wiring Layout for Static Oven Wiring Layout for Convection Oven ...
Страница 36: ...34 ...
Страница 37: ...35 ...