11
The regulator connections are
3
/
4
" BSP female.
The connection to the appliance is
3
/
4
" BSP male.
(Refer to the “Specifications” section for the gas supply location dimensions).
NOTE: A Manual Isolation Valve must be fitted to the individual appliance supply line.
3.
Correctly locate the appliance into its final operating position and using a spirit level, adjust the legs
so that the unit is level and at the correct height.
4.
Connect the gas supply to the appliance. A suitable jointing compound which resists the breakdown
action of LPG must be used on every gas line connection, unless compression fittings are used.
5.
Check all gas connections for leakages using soapy water or other gas detecting equipment.
NOTE: The burner operating pressure is to be measured at
the manifold test point with 2 burners operating at
‘Full’ setting.
6.
Check that the gas operating pressure is as shown in
‘Specifications’ section.
7.
Turn off the mains gas supply and bleed the gas out of
the appliance gas lines.
8.
Turn on the gas supply and the appliance.
9.
Verify the operating pressure remains correct.
Electrical Connection
NOTE: ALL ELECTRICAL CONNECTIONS MUST ONLY BE CARRIED OUT BY AN AUTHORISED
PERSON.
Each appliance should be connected to an adequately
protected power supply and isolation switch mounted
adjacent to, but not behind the appliance. This switch
must be clearly marked and readily accessible in case of
fire.
1.
Check that the electricity supply is correct as
shown on the Rating Plate attached to the lower
front hand side of the front sill panel.
2.
The supply terminal connections are located at the
rear of the appliance. Refer to ‘Electrical
Connections’ in the ‘Dimensions’ section of the
manual.
3.
Open the oven door and remove the oven control
panel to allow connection access for the electrical
supply.
4.
Connect the mains supply to L1, L2 and L3
connection terminals. Refer to the 'Electrical
Supply Requirements' section for connection
details.
NOTE: This appliance can be converted from 3 Phase to Single Phase supply by connecting the
single phase input to L1 and adding a bridge wire between the L1, L2 and L3 connections,
(refer to Fig 3 opposite and the information shown in the 'Electrical Supply Requirements
Table' in the 'Specifications' Section).
Installation
WARNING:
D
O
NOT
USE
A
NAKED
FLAME
TO
CHECK
FOR
GAS
LEAKAGES
.
Fig 2
Manifold Test
Point
WARNING:
T
HIS
APPLIANCE
MUST
BE
EARTHED
. I
F
THE
SUPPLY
CORD
IS
DAMAGED
,
IT
MUST
BE
REPLACED
BY
A
SUITABLY
QUALIFIED
PERSON
IN
ORDER
TO
AVOID
A
HAZARD
.
Add bridging
wires between
Neutral
supply
connection to
N
Phase
supply
connection to
L1
P
N
Fig 3
Содержание Evolution GE505
Страница 8: ...6 Dimensions Dimensions GE505 GE54 Refer to Page 8 for Cook Top Options Dimensions GE506 GE56 ...
Страница 9: ...7 Dimensions Dimensions GE508 GE58 Refer to Page 8 for Cook Top Options ...
Страница 25: ...23 Wiring Schematic Static Ovens GE505 GE506 GE508 Series ...
Страница 26: ...24 Wiring Schematic Convection Ovens GE54 GE56 GE58 Series ...
Страница 27: ...25 Wiring Schematics Wiring Layout for Static Oven Wiring Layout for Convection Oven ...
Страница 36: ...34 ...
Страница 37: ...35 ...