10
The regulator connections are
3
/
4
" BSP female.
The connection to the appliance is
3
/
4
" BSP male.
(Refer to the “Specifications” section for the gas supply location dimensions).
NOTE: A Manual Isolation Valve must be fitted to the individual appliance supply line.
3.
Correctly locate the appliance into its final operating position and using a spirit level, adjust the legs
so that the appliance is level and at the correct height.
4.
Connect the gas supply to the appliance. A suitable jointing compound which resists the breakdown
action of LPG must be used on every gas line connection, unless compression fittings are used.
5.
Check all gas connections for leakages using soapy water or other gas detecting equipment.
6.
Check that the gas operating pressure is as shown in the ‘Specifications’ section.
NOTE: The burner operating pressure is to be measured at the manifold test point with two burners
operating at ‘Full’ setting.
7.
Turn ‘OFF’ the mains gas supply and bleed the gas out of
the appliance gas lines.
8.
Turn ‘ON’ the gas supply and the appliance.
9.
Verify the operating pressure remains correct.
Electrical Connection
NOTE: ALL ELECTRICAL CONNECTIONS MUST ONLY BE CARRIED
OUT BY AN AUTHORISED PERSON.
Each appliance should be connected to an adequately protected power supply and isolation switch mounted
adjacent to, but not behind the appliance. This switch must be clearly marked and readily accessible in
case of fire.
1.
Check that the electricity supply is correct as shown on the Rating Plate attached to the front right
hand corner of the bottom sill.
2.
The appliance is fitted with a 10 Amp, 3 pin plug cordset for connection to a properly earthed, 3 pin
switched electrical socket.
Commissioning
1.
Before leaving the new installation;
a. Check the following functions in accordance with the operating instructions specified in the
“Operation” section of this manual.
•
Lighting the Griddle.
•
Light the Open Burners. (F - Flame Failure Option).
•
Light the Open Burners. (PF - Pilot and Flame Failure Option).
•
Check the Low Fire Burner operation.
•
Check the High Fire Burner operation.
•
Light the Oven Pilot and Main Burners.
•
Check the Oven Main Burner Thermostat operation.
•
Check the Oven Fan operation.
b. Ensure that the operator has been instructed in the areas of correct lighting, operation, and
shutdown procedure for the appliance.
2.
This manual must be kept by the owner for future reference, and a record of the
Date of
Purchase,
Date of Installation
and
Serial Number of the Appliance
recorded and kept with
this manual.
(
These details can be found on the Rating Plate attached to the front right
hand corner of the bottom sill. Refer to the ‘Gas Connection’ section).
NOTE: If for some reason it is not possible to get the appliance to operate correctly, shut off the
gas supply and contact the supplier of this appliance.
Installation
Fig 2
Manifold
Test Point
WARNING:
D
O
NOT
USE
A
NAKED
FLAME
TO
CHECK
FOR
GAS
LEAKAGES
.