6
Service Procedures
Revision 1/
©
Moffat Ltd, January 2007
Blue Seal Evolution Series Electric Bratt Pans
18
1) Remove three front covers (refer 6.1.1,
6.1.2 and 6.1.3)
2) Remove two 4mm hex screws securing plate
for over-temp and thermostat capillaries and
withdraw overtemp capillary.
Figure 6.2.5b
Figure 6.2.5a
6.2.5 Over-temp
Thermostat
3) Unscrew nut securing over-temp to bracket
and remove switch from behind bracket.
4) Disconnect wiring from terminals.
5) Replace and reassemble in reverse order.
1) Remove left front panel (refer 6.1.2).
2) Remove two screws securing microswitch to
base of unit.
6.2.6
Pan Microswitch
Figure 6.2.6
3) Transfer wiring to new microswitch.
4) Reassemble in reverse order.
Microswitch
1) Remove left front panel (refer 6.1.2)
2) Isolate unit from water supply.
3) Remove two nuts securing water piping to
valve.
4) Undo two screws securing water valve to the
mounting panel.
Figure 6.2.7
6.2.7 Water Valve
5) Disconnect wires from solenoid on water
valve.
6) Remove bracket and brass unions from water
valve.
7) Replace water valve and reassemble in re-
verse order.
Water valve
Two screws
Solenoid
Capillaries
Overtemp switch