Blue Rhino UniFlame GAD700SP Скачать руководство пользователя страница 7

Contact 1.800.762.1142 for assistance. Do not return to place of purchase.

page no.

Checking for Leaks

 WARNING: Before using this outdoor 

fireplace, make sure you have read, understand 
and are following all information provided in 
the Dangers and Warnings presented on page 
2. Failure to follow those instructions can cause 
death, serious injury or property damage.

Burner Connections

Make sure the regulator valve and hose 
connections are securely fastened to the burner 
and the tank.  

If your unit was assembled for you, visually check 
the connection between the burner pipe and orifice.  
Make sure the burner pipe fits over the orifice.  

 WARNING: Failure to inspect this connection 

or follow these instructions could cause a fire 
or an explosion which can cause death, serious 
bodily injury, or damage to property.  

Please refer to diagram for proper installation.  

If the burner pipe does not rest flush to the orifice, 
please contact 1.800.762.1142 for assistance.

Tank/Gas Line Connection

Make 2-3 oz. of leak solution by mixing one part 
liquid dishwashing soap with three parts water.  

Make sure control knob is OFF.  

 Turn LP gas tank ON at valve.

  Spoon leak check solution at all “x” locations

 If any bubbles appear turn LP gas tank OFF, 
reconnect and re-test. If you continue to see 
bubbles after several attempts, disconnect LP gas 
source and contact 1.800.762.1142 for assistance.

If no bubbles appear after one minute turn tank 
OFF, wipe away solution and proceed.

Lighting

1.   Make sure there are no obstructions of airflow to 

the gas unit. Spiders and insects can nest within 
and clog the burner / venturi tube at the orifice.  
A clogged burner tube can lead to a fire beneath 
the appliance.

2. Control knob must be in the “OFF” position.

3. Turn on gas at LP gas tank.

4.  Push and turn control knob counterclockwise to 

“LOW”.

5.  Press the electronic igniter and hold for  

5 seconds to light burner.

6.  Release control knob after 45 seconds. 

7.  If ignition does not occur in 45 seconds, turn 

burner control knob “OFF”, wait 5 minutes, fan 
with newspaper or magazine, and repeat lighting 
procedure.  

8.  If igniter does not light burner, use a long match 

or long butane lighter. 

 CAUTION: Before Lighting - Using a shovel 

to carefully move the lava rocks to access the 
burner.

 

a.  Wearing Heat reistant gloves, position the 

lit long match or lit long butane lighter 
near the side of the burner.

 

b.  Turn control knob counterclockwise to 

“LOW”.

 

c. Remove long match/long butane lighter.

 CAUTION: After Lighting - Using a shovel 

and heat resistant gloves, carefully move the 
lava rocks back to their proper position, being 
careful to avoid the flame.

Installing LP Gas Tank

To operate you will need (1) precision-filled standard grill LP gas 
tank (20#) with external valve threads.

Note: 

An empty standard grill LP gas tank weighs approximately  

18 lbs.  A precision-filled standard grill LP gas tank should weigh 
no more than 38 lbs.

Need a tank of gas? 

Try tank exchange service. It’s easy, fast, safe, 

and available at tens of thousands of conveniently located retail outlets 
nationwide. You can purchase a new full tank or exchange your empty for a 
precision filled one.

Insert LP Gas Tank

 WARNING: Make sure LP gas tank valve is closed. Close by turning valve clockwise.

Place precision filled LP gas tank upright into hole in outdoor fireplace body so it is arranged 
for vapor withdrawal.

Secure LP Gas Tank

Secure tank by sliding tank retainer chain around the LP gas tank and insert peg into LP gas 
tank tray.

Note

: Peg must be inserted into LP gas tank when tank is in LP gas tank tray.

Connect LP Gas Tank

Before connecting, be sure that there is no debris caught in 
the head of the LP gas tank, head of the regulator valve or in 
the head of the burner and burner ports.     

 Connect gas line to tank by turning knob clockwise until it 
stops.

Disconnect LP Gas Tank

Before disconnecting make sure the LP gas tank valve is OFF.

Disconnect gas line to tank by turning knob counterclockwise 
until it is loose.

LP Gas 
Connection

LP Gas Valve 
with Orifice

Burners

X

X

X

X

X

LP Gas Tank Valve

Control Knob

Operating Instructions

Proper flame height.

Lighting Rod Placement

K

Содержание UniFlame GAD700SP

Страница 1: ...andard CAN CGA B149 1 installation code for propane burning appliances and equipment California Proposition 65 Chemicals known to the State of California to cause cancer birth defects or other reprodu...

Страница 2: ...our local fire department for details on outdoor burning When using this outdoor fireplace exercise the same precautions you would with any open fire The use of alcohol prescription or non prescriptio...

Страница 3: ...13 Tank Guard 55 05 458 14 LP Gas Tank Retaining Chain 55 05 447 15 LP Gas Tank Tray Peg 55 05 449 16 Base Support Bar 55 05 429 17 Left Front Leg 55 05 700 18 Left Door 55 05 690 19 Door Support Leg...

Страница 4: ...erial number available for reference For Easiest Assembly To avoid losing any small components or hardware assemble your product on a hard level surface that does not have cracks or openings 5 Attach...

Страница 5: ...all hardware connections by hand first Once the step is completed go back and fully tighten all hardware Follow all steps in order to properly assemble your product 3 Attach Side Panels Back Legs and...

Страница 6: ...nstructions continued 10 Attach Doors C x 2 12 Insert Battery E x 1 11 Place Wood Grid and Lava Rocks Do NOT dump lava rocks out of package Carefully place lava rocks by hand so dust does not clog bur...

Страница 7: ...seconds turn burner control knob OFF wait 5 minutes fan with newspaper or magazine and repeat lighting procedure 8 If igniter does not light burner use a long match or long butane lighter CAUTION Bef...

Страница 8: ...ial and workmanship Vendor may require reasonable proof of your date of purchase Therefore you should retain your sales slip or invoice This Limited Warranty shall be limited to the repair or replacem...

Страница 9: ...ean burner ports Sudden drop in gas flow or reduced flame height Out of gas Check for gas in the LP gas tank Excess flow safety device may have been activated Turn control knob to OFF wait 30 seconds...

Страница 10: ...LP Gas Outdoor Fireplace Model No GAD700SP...

Страница 11: ...Contact 1 800 762 1142 for assistance Do not return to place of purchase page no 11...

Страница 12: ...LP Gas Outdoor Fireplace Model No GAD700SP...

Отзывы: