Appendix A: Technical Specifications

Operation Mode

Automatic Pipetting (AUTO), Multiple 

Dispensing (MD), Mixing (MIX), 

Sequential Aspirating/Dispensing 

(SE), System Setup (SYS)

Memories

9 sets

Aspirating/Dispensing 

Speed

5 speeds

Auto-calibration

Yes

Power Engine

High precision stepping motor

Power Saving

Yes, after 10 minutes

Power Adaptor

100/120/220/24

0 V AC-DC 3.6 V

Acoustic Indication

Yes

Autoclavable

Yes, for lower part only

Operating Temperature

5 ~

50

o

C

Operating Humidity

RH: 0 ~ 85%

Battery

900 mAh/3.6 V or above

Battery Charger

Option

al

Stand for 3 units

Option

al

Certification

Complies with CE, Class A 

(EN60101-1-2, EN50082-1, EN 

55011)

Complies with ISO-8655/ DIN 12650

Note: 

1. U.S. patent pending
2. Specifications are subject to change without prior notice

28

Содержание BluePette

Страница 1: ...BluePette Single and Multichannel Electronic Pipettes User Manual Version 1 0 Copyright 2018 Blue Ray Biotech Corp All Rights Reserved...

Страница 2: ......

Страница 3: ...ery 5 3 3 Charging the Battery 5 3 4 Start Pipetting 7 3 5 Hanger Installation 8 4 Overview 8 4 1 Keypad Function 10 4 2 Acoustic Signals 11 5 Function Map 12 6 SYS System Mode 13 6 1 Aspirating Speed...

Страница 4: ...19 10 2 SD Sequential Dispensing Mode 21 11 Sterilization 22 11 1 Disassemble Lower Part 23 11 2 Reassemble Lower Part 24 12 Maintenance 25 13 Troubleshooting 25 Appendix A Technical Specifications 28...

Страница 5: ...potentially explosive environment or with potentially explosive chemicals 2 When using organic solvents or corrosive chemicals please ensure that they are compatible with the pipette tips and the pip...

Страница 6: ...ed original charger unit to charge the battery 9 Do not use a leaking battery 10 If charging is not completed within the specified time period unplug the charger and discontinue charging immediately 1...

Страница 7: ...h accuracy and precision Force savings Useful practical operation protocols such as Automatic Pipetting AUTO Multiple Dispensing MD Mixing MIX and Sequential Aspirating Dispensing SE etc Storage of up...

Страница 8: ...nger and accessories Pipette tips 1 battery charger set and 1 extra battery If there are any items missing damaged or not according to your order please contact your distributor or sales representativ...

Страница 9: ...ote After the battery is inserted the pipette will automatically carry out a calibration routine 3 3 Charging the Battery Internal Charging Circuit Insert the battery into the battery compartment Inse...

Страница 10: ...ing will stop and the pipette will beep once to remind the user Figure 3 Using the internal charging circuit to charge the battery Note 1 For safety concerns the pipette shall not be used during the c...

Страница 11: ...witched off if it s not in use for more than 10 minutes Select the desired function mode and settings refer to the following chapters 6 10 before pipetting After the initial set up please attach the c...

Страница 12: ...de accessory bag as shown in Figure 5 The finger rest can be attached to the hanger to keep the pipette in a vertical position Figure 5 Hanger installation 4 Overview This section presents an overview...

Страница 13: ...r Alarm Blow Out Reverse Pipetting Front View Side View LCD Display Keypad Bushing Lower Part Tip Fitting Tip Ejector Battery Cover Start Button Reset Button Connecting Nut Start Button EXIST Button B...

Страница 14: ...parameter Reset Piston automatically determines the home position Start START Activates aspirating dispensing Replace button Tip Ejector TIP Ejects the tips Tips On Efficient Operation START button ca...

Страница 15: ...zing yourself with the operating procedure of the BluePette They can also be switched off if required see Section 6 3 Acoustic Sound Operation Low tone beep Aspirating High tone beep Dispensing Tip Ej...

Страница 16: ...e Figure 8 Figure 8 Function map Function Map AUTO Functio n Mode Aspirating Speed Dispensing Number COUNT Mix Number COUNT Dispensing Speed Acoustic Signals Program Recall Reverse Pipetting Tip Eject...

Страница 17: ...in memory you have to complete the whole setting procedure and press SET when the LCD displays 2 You can use the Up Down button to move back and forth to the previous function settings 6 1 Aspirating...

Страница 18: ...Press Up Down to select the preference On Off 3 Press SET to confirm the selection and move to the Tip Ejection Alarm setting 6 4 Tip Ejector Alarm The tip ejector alarm is designed to remind the use...

Страница 19: ...t is important to withdraw the tip quickly from the dispensing sample vessel after dispense if Blow out is selected because the piston will retract a short distance for creating the blow out volume 6...

Страница 20: ...Storage Locations 1 Complete the setup of function mode e g AUTO MD MIX mode 2 Press and hold Down for 3 seconds to enter PROG mode 3 Press Up Down to select PROG number from 01 09 4 Press SET to con...

Страница 21: ...selection 3 Use Up Down to select the desired pipetting volume 4 Press SET to confirm selected volume and readiness for pipetting Tip You may use the START button to replace Up to speed up the volume...

Страница 22: ...pipetting count The pipetting volume will show the total aspirating volume 8 After the settings are completed first press the START button to aspirate the sample according to the pipetting volume Nex...

Страница 23: ...n After the completion of mixing pressing the START button will re activate the mixing process until the user changes the function mode 10 SE Sequential Aspirating Dispensing Mode SE mode includes SA...

Страница 24: ...hat the pipette is ready for liquid pick up Press the START button to aspirate the samples will appear to remind users to create an air gap between sample aspirations 11 When the aspirations are compl...

Страница 25: ...lashing 5 Press SET to confirm the selection 6 Under symbol 01 will appear Press Up Down to set the volume of the first dispensing 7 Press SET to confirm the selection 8 Repeat steps 6 and 7 to set th...

Страница 26: ...t of the pipette can be steam autoclaved 121 o C 1 bar 20 minutes The autoclaved parts must be allowed to dry completely at room temperature for at least 2 hours You can follow Figures 10 13 to disass...

Страница 27: ...as shown in Figure 10 3 Pull the lower part downward slowly until the cylinder lock appears as shown in Figure 11 4 Please place the pipette on a flat surface Push the cylinder lock downwards until yo...

Страница 28: ...part of the pipette 1 Press the START button or any button of the keypad to make the step motor shaft retract inside of upper part for 1 cm The step motor will automatically retract inside of upper l...

Страница 29: ...ubricate the pipette more frequently Only trained representatives or users are recommended to lubricate the piston Please use the lubricant as offered by the supplier only It is recommended to check t...

Страница 30: ...d service provider for repair Symptom Possible Cause Solution Err 01 Bad battery Charge the battery Bad power adaptor Replace the power adaptor Err 02 Auto calibration is not working Press the button...

Страница 31: ...sh away the foreign objects Piston blocks Lubricate piston Power on failure Bad battery contact Reinsert the battery Rusted battery contact Replace with new battery Dead battery Charge the battery Fun...

Страница 32: ...tor Power Saving Yes after 10 minutes Power Adaptor 100 120 220 240 V AC DC 3 6 V Acoustic Indication Yes Autoclavable Yes for lower part only Operating Temperature 5 50 o C Operating Humidity RH 0 85...

Страница 33: ...lat head screwdriver or other tool to rotate the tip ejector height adjustment nut By rotating the nut in counter clockwise direction the tip ejector will move closer to the mouth of tip fitting This...

Страница 34: ...caused by excessive tear and wear or damage due to shipping accident abuse misuse problems with electrical power or usage not in accordance with product instructions or if other than original spare p...

Страница 35: ...duct Name BluePette Single 8 channel Electronic Pipettes Model Names B20 1 B200 1 B1000 1 B20 8 B200 8 All models comply with the following European standards EMC EN55011 Class A Safety EN61010 1 1 2...

Страница 36: ......

Страница 37: ......

Страница 38: ......

Страница 39: ......

Страница 40: ...www blue raybio com 4F NO 31 Sec 2 Chang an E Rd ZhongShan Dist Taipei City 10456 Taiwan R O C P N 401 apbr00 10...

Отзывы: