background image

 

Blue Phantom True Anatomy™ Series Use and Care Instructions 

   

Page 7/7 

2.

 

Inserting the new leg tissue insert module.

 Place the superior tip (widest portion) of the tissue insert module into 

the groin of the leg. Use one hand to stabilize the entire model and the other to squeeze the lateral sides of the 
tissue insert medially while pushing downward into the foam leg. Working your way down to the knee, make 
adjustments to the ultrasound insert so that the tissue sits flush with the foam frame.  

3.

 

Place the alternate side (skinniest portion) of the insert into the leg model until it is positioned flush with the 
surface of the surrounding foam tissue.

 

Cleaning and Storing Your Model 

After each use your model can be easily cleaned using mild soapy water.  Use a soft cloth to dry after cleaning.  It is preferred to 
dab the model dry rather than rubbing as this will help preserve the finish of the tissue insert model by minimizing scuffing.  The 
model can be stored at room temperature either in the storage container or in the open. 

Blue Phantom Warranty 

Blue Phantom takes pride in its quality design and manufacturing standards. Our products are warranted to you by Blue Phantom 
for 1 year from the date of purchase against defects in workmanship and materials. During the warranty period, a defective part 
or product will be replaced either with a new or reconditioned part or product, depending on the availability at the time of 
placement.  

This warranty covers normal consumer usage and does not cover damage incurred through use not consistent with the product 
design. Failure that results from alteration, accident, misuse, vandalism, or neglect is not covered under this warranty. This 
warranty does not extend to any products that have been used in violation of written instructions.  

Help and Technical Assistance 

Blue Phantom is committed to providing you with superb products and uncompromising customer support. Should you require 
assistance feel free to contact us directly at (425) 881-8830.  

 

Содержание BPL400

Страница 1: ...Blue Phantom True Anatomy Series Use and Care Instructions Page 1 7 ...

Страница 2: ...Phantom Warranty Blue Phantom takes pride in its quality design and manufacturing standards Our products are warranted to you by Blue Phantom for 1 year from the date of purchase against defects in workmanship and materials During the warranty period a defective part or product will be replaced either with a new or reconditioned part or product depending on the availability at the time This warran...

Страница 3: ...arp objects as to not accidentally injure yourself during training 12 Servicing Do not attempt to service this unit yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified personnel 13 Power Sources units with electronics should only be operated from the type of power source indicated on the marking label If you are not sure of t...

Страница 4: ...position 2 Place ultrasound gel on the model or on the ultrasound transducer in adequate quantities so that the probe slides effortlessly across the surface of the model Add more gel as necessary 3 Adjust the ultrasound system controls per the manufacturer s instructions increasing and decreasing the depth and gain controls until the desired image is obtained Using Needles and Catheters USE A SHAR...

Страница 5: ...dent upon the amount of fluid removed during simulation training the phantom vessels can be easily refilled and air can be purged from the system without difficulty using the following method A Determine if the fluid filled structures within your model require refilling The presence of air within a structure or a noticeably low fluid volume indicates the fluid filled structures require refilling 1...

Страница 6: ...el D Be careful not to overfill the vessels because this can cause previously cannulated sites to leak small amounts of fluid If you notice this occurring simply remove a small successive amounts of fluid until the vessel has retained its original size CAUTION Use refill solution as directed Not intended for human consumption If accidental consumption occurs drink a glass of water and consult a ph...

Страница 7: ...issue insert model by minimizing scuffing The model can be stored at room temperature either in the storage container or in the open Blue Phantom Warranty Blue Phantom takes pride in its quality design and manufacturing standards Our products are warranted to you by Blue Phantom for 1 year from the date of purchase against defects in workmanship and materials During the warranty period a defective...

Отзывы: