Blue Coat ProxySG 9000 Series Скачать руководство пользователя страница 2

Disclaimer

THIS DOCUMENT IS PROVIDED “AS IS” WITHOUT ANY EXPRESS OR IMPLIED WARRANTY OF ANY KIND, INCLUDING WARRANTIES OF MERCHANTABIL-
ITY, NONINFRINGEMENT OF INTELLECTUAL PROPERTY, OR FITNESS FOR ANY PARTICULAR PURPOSE. IN NO EVENT SHALL BLUE COAT OR ITS SUPPLIERS 
BE LIABLE FOR ANY DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF PROFITS, BUSINESS INTERRUPTION, OR 
LOSS OF INFORMATION) ARISING OUT OF THE USE OF OR INABILITY TO USE THIS DOCUMENT, OR THE PRODUCTS DESCRIBED HEREIN, EVEN IF BLUE 
COAT HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. BECAUSE SOME JURISDICTIONS PROHIBIT THE EXCLUSION OR LIMITATION OF LIA-
BILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, THE ABOVE LIMITATION MAY NOT APPLY TO YOU. Blue Coat and its suppliers further do not 
warrant the accuracy or completeness of the information, text, graphics, links or other items contained within this document, or assume liability 
for any incidental, indirect, special or consequential damages in connection with the furnishing, performance, or use of this document. Blue Coat 
may make changes to this document, or to the products described herein, at any time without notice. Blue Coat makes no commitment to update 
this document.

Copyright/Trademarks/Patents

Copyright© 1999-2012 Blue Coat Systems, Inc. All rights reserved worldwide. No part of this document may be 
reproduced by any means nor modified, decompiled, disassembled, published or distributed, in whole or in part, or 
translated to any electronic medium or other means without the written consent of Blue Coat Systems, Inc. All right, 
title and interest in and to the Software and documentation are and shall remain the exclusive property of Blue Coat 
Systems, Inc. and its licensors. ProxyAV™, ProxyOne™, CacheOS™, SGOS™,  SG™, Spyware Interceptor™, 
Scope™, ProxyRA Connector™, ProxyRA Manager™, Remote Access™ and MACH5™ are trademarks of Blue 
Coat Systems, Inc. and CacheFlow®, Blue Coat®, Accelerating The Internet®, ProxySG®, WinProxy®, 
PacketShaper®, PacketShaper Xpress®, PolicyCenter®, PacketWise®, AccessNow®, Ositis®, Powering Internet 
Management®, The Ultimate Internet Sharing Solution®, Cerberian®, Permeo®, Permeo Technologies, Inc.®, and 
the Cerberian and Permeo logos are registered trademarks of Blue Coat Systems, Inc. All other trademarks 
contained in this document and in the Software are the property of their respective owners.

BLUE COAT SYSTEMS, INC. AND BLUE COAT SYSTEMS INTERNATIONAL SARL (COLLECTIVELY “BLUE 
COAT”) DISCLAIM ALL WARRANTIES, CONDITIONS OR OTHER TERMS, EXPRESS OR IMPLIED, STATUTORY 
OR OTHERWISE, ON SOFTWARE AND DOCUMENTATION FURNISHED HEREUNDER INCLUDING WITHOUT 
LIMITATION THE WARRANTIES OF DESIGN, MERCHANTABILITY OR FITNESS FOR A PARTICULAR 
PURPOSE AND NONINFRINGEMENT.  IN NO EVENT SHALL BLUE COAT, ITS SUPPLIERS OR ITS LICENSORS 
BE LIABLE FOR ANY DAMAGES, WHETHER ARISING IN TORT, CONTRACT OR ANY OTHER LEGAL THEORY 
EVEN IF BLUE COAT SYSTEMS, INC. HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.

Americas:

Rest of the World:

Blue Coat Systems, Inc.

Blue Coat Systems International SARL

420 N. Mary Ave.

3a Route des Arsenaux

Sunnyvale, CA 94085

1700 Fribourg, Switzerland

http://www.bluecoat.com

Revision History

Dec. 2009

Rev A.0

Sep. 2010

Rev A.1

Dec. 2011

Rev B.0

Содержание ProxySG 9000 Series

Страница 1: ...Tamper Evident Panel and Label Installation For Compliance Model Number 9000 ProxySG 9000 Series FIPS Compliance Guide ...

Страница 2: ...s without the written consent of Blue Coat Systems Inc All right title and interest in and to the Software and documentation are and shall remain the exclusive property of Blue Coat Systems Inc and its licensors ProxyAV ProxyOne CacheOS SGOS SG Spyware Interceptor Scope ProxyRA Connector ProxyRA Manager Remote Access and MACH5 are trademarks of Blue Coat Systems Inc and CacheFlow Blue Coat Acceler...

Страница 3: ... of the tasks involved to make your network environment Federal Information Processing Standards FIPS compliant Kit Contents This kit contains the following materials Name Part 4 Long Labels Note Two 2 long labels are required to secure the appliance Additional labels are included for reapplication purposes 14 Short Labels Note Seven 7 short labels are required to secure the appliance Additional l...

Страница 4: ...optional If you are asked to perform this task Blue Coat recommends creating a matrix that associates Blue Coat appliances with a physical location then record each serial number as you add labels Label Precautions and Application Tips Adhere to the following when applying the tamper evident labels The minimum temperature of the environment must be 35 degrees Farenheit After application the labels...

Страница 5: ...t correctly adhere to the surface To clean the adhesive residue and other contaminants after a label is removed Step 1 Remove traces of the silicone adhesive evidence by throughly cleaning the surface using an alcohol swab Step 2 Remove any remaining surface contaminants using a cotton round Step 3 Repeat if necessary Before You Begin If the Blue Coat appliance is already rack mounted and operatin...

Страница 6: ...ter which covers the primary ventilation outlet and a smaller shutter which covers the secondary outlet Both shutters are installed using the included flat head screws The image below shows the louvered shutters and security labels installed on a SG9000 To install the louvered shutters on an SG9000 series appliance Step 1 Align the large louvered shutter mounting points against the screw locations...

Страница 7: ...SG9000 Tamper Evident Panel and Label Installation 7 Step 2 Align the small louvered shutters against the mounting points shown below and secure with two flat head screws Step 2 Flat Head Screw x2 ...

Страница 8: ...ge below illustrates the tamper evident features of the label To secure the SG9000 series appliance using the high security labels Step 1 Use alcohol swabs to clean the label location surface this ensures complete adhesion Verify that all surfaces are dry before applying the labels Step 2 Apply one long label over each power supply unit as illustrated below When applying the labels make sure there...

Страница 9: ... Tamper Evident Panel and Label Installation 9 Step 3 Apply one short label across the large louvered shutter and over the chassis Be sure that the label covers both parts in equal amounts Step 3 Short Label ...

Страница 10: ...liance Step 5 Apply one short label across the center of the small louvered shutter Make sure it covers both the small louvered shutter and extends over the right edge of the appliance Step 6 Apply one short label vertically over the large louvered shutter and over the top edge of the appliance Make sure the label contacts all edges of the surfaces without any gaps Step 4 5 Short Label Step 4 Step...

Страница 11: ...sis The label should be placed approximately three quarters of an inch beyond the release tab Step 8 Rack mount the appliance Refer to the SG9000 Quick Start Guide for instructions and safety information on rack mounting the appliance Step 9 Reinstall the power cables Step 10 Reinstall the network cables Step 11 Power on the system Step 7 Short Label x1 ...

Страница 12: ...sis and bezel to prevent unauthorized access to the front panel and hard disk carriers Each label should be placed on the opposite ends of the appliance as shown below Note The chassis bezel labels are destroyed each time the bezel is opened Be sure to re secure the bezel after servicing the appliance x2 Step 13 Short Label ...

Страница 13: ...SG9000 Tamper Evident Panel and Label Installation 13 ...

Страница 14: ...www bluecoat com 231 03063 REV B 0 ...

Отзывы: