14
• Unwind the power cord completely and plug the GFCI into a grounded 120 volt outlet. Press the
‘
reset
’ button on the GFCI box
(Fig. 21)
. The indicator window should show a red color. This must
be done each time the unit is plugged in.
• Release the safety lock button on the spray gun by pressing the safety lock button from right to
left
(Fig. 22)
. While pointing the spray gun in a safe direction, squeeze the trigger on the spray
gun until there is a steady stream of water, letting the water and air out of the hose.
• Turn the power switch to the ‘ON’ (|) position. The unit will turn on for 1 - 2 seconds and shut off,
this is a normal function of the (TSS) auto start feature. Squeeze the spray gun trigger to begin
pressure washing.
• Squeezing rapidly will cause the (TSS) feature to miss an on/off cycle that may prevent from
turning on while squeezing trigger after rapid squeezing. Use slow deliberate trigger pulls to
avoid such symptoms.
H
oW
t
o
c
Lean
Cleaning nozzles
•
A clogged or partially clogged nozzle can cause significant reduction of water pressure coming out
of the nozzle and/or cause the unit to pulsate while spraying.
• Turn off the unit
• Turn off the water supply to the unit
• Relieve any pressure trapped in the hose by squeezing the trigger 2-3 times, and then lock the
spray gun by pushing the lock button from left to right.
Fig. 22
2
1
Trigger
Press to
Unlock
2
1
Trigger
Press to
Lock
Fig.21