Your unit will warn you when there is
a problem detected. Use the chart
below to determine your notifications
and light patterns.
ADVANCED TEXT NOTIFICATION
LIGHT BLINKING PATTERNS
Status Light
Green
Flashing
Sleeping or on
battery backup
power
Green Blinking Not ready
attempting to
connect to cellular
network
Green Solid
Ready
Red Solid
Cellular signal not
present
Red Blinking
Fast
An error occurred
Low Battery
Light
Off
Batteries normal
Flashing
Batteries low
or critically low
Water
Sensor
Lights
Off
Water not
detected
Toggles On/Off
with audible
alarm
Water detected
Operating Instructions and Parts Manual
BCPA1
7
www.blueangelpumps.com/AdvancedText
Your unit will warn you when there is
a problem detected. Use the chart
below to determine your audible
alarms.
ADVANCED TEXT NOTIFICATION
AUDIBLE ALARMS
Alert
Event Type
One Second
Beep
Water sensor
activated
One Second
Beep
Power on
(after activation)
(3) One Second
Beeps
Power on
(pre-activation)
1/4 Second
Beep Every 30
Seconds
Battery low or
critically low
One Second
Beep
Push to test
(2) Chirps
Successful
programming
(5) Chirps
Cellular service
or transmission
error
(3) 1/4 Second
Beeps
Incorrect or
unsuccessful
programming
error
Definitions:
Flashing
- Light will turn on very briefly and then it turns off for two seconds
Blinking
- Light will toggle On/Off every second