Fourth, if the current stay in 40mA, we should check the circuit around flash, when CPU
calling program from flash fail, the current will stay in 40mA, re-download the software or
change a new flash or CPU.
Fail to power on
N
Check if the battery
Change
is OK.
battery
Y
Check if battery
N
Resold
connects solder ok
connect
Y
Is power key OK?
N
Change a new
power key
Y
Check each power
N
Re-solder or
out of PMU
replace U1001
Y
Re-download
Y
Software
OK
N
Resold or replace
Y
U502
OK
N
Y
Resold or replace
OK
U0401
3.2 Fail to charge
Check charging circuit related component, check below information in sequence:
First, checks whether boot normal use the battery, if not check battery connector solder ok
or not;
Second, check USB connector on board solder ok or not;
Third, check T1710 whether reverse; check C1802 resistance is very big or not.