background image

SUGGESTED CLEARANCES FROM

UNIT MUST BE INSTALLED IN AN ALL METAL COUNTER

CLEARANCES

BACK

SIDE

BOTTOM

FRONT

(51)

2

2

(51)

(171)

6 3/4

(105)

4 1/8

SEE CONDITIONS OF ACCEPTABILITY BELOW

UNIT TO THE NEAREST SURFACE

WARMER FLANGE

GASKET

WELLSLOK

SCREWDRIVER

COUNTERTOP

TO FABRICATE AND INSTALL:

1. Lay out cutout dimensions on countertop and control

panel as shown in cutout details.

2. Cut and/or drill holes as required in countertop and apron.

3. Do not disconnect control lead wires when installing.

4. To install, locate warmer and control over counter cut-out

Pass control through opening, then mount control electrical box

to rear of apron.

5. Remove warmer and apply a bead of silicone sealant to

gasket on underside of warmer flange, then seat warmer onto

countertop. Properly position.

6. From underneath, insert screwdriver into slots on Wellslok

frame and twist ears outward (counter-clockwise) to secure flange

tightly to countertop (see detail above).

7. Mount master control panel to front of counter apron using

screws supplied.

NOTE:  The SS-206TD warmer is supplied with a drain hole at

one end and a 1/2 inch female N.P.T. drain nipple.

NOTE: INSTALLATION MUST MEET LOCAL AND NATIONAL PLUMBING

      AND ELECTRICAL CODES.

THE INSTALLATION OF RECOGNIZED COMPONENT UNITS REQUIRES
ADDITIONAL EVALUATIONS TO UNDERWRITERS LABORATORIES INC.
STANDARDS.
INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY OUTLINED
BELOW UPON INSTALLATION:
1. This appliance shall be installed in an all metal counter with

suitable wiring and control enclosures conforming to national and

local standards.

2. Electrical component temperatures, including wiring, within and

surrounding the appliance must be monitored in the end use

installation for suitability.

3. Electrical grounding of all dead metal parts must be reliably

connected to the grounding means of the appliance and must

comply with requirements outlined in the appropriate Underwriters

Laboratories Inc. classification, national and local electrical codes.

4. Increased clearances are required if storage of combustible

materials is in close proximity to this appliance.

5. Unit shall be accessible for servicing from bottom.

6. The name/rating plate information shall be accessible.

7. For water and waste connections: This appliance is to be

installed to comply with applicable federal, state and local

plumbing codes.

PRODUCT DIMENSIONS

CUTOUT DETAILS

90°C MIN.

90°C MIN.

90°C MIN.

14 AWG Cu

14 AWG Cu

14 AWG Cu

SINGLE

SINGLE

SINGLE

5.0

4.3

10.0

1200

900

1200

120

208

240

ALL MODELS WITH A 'D' SUFFIX HAVE THE SAME ELECTRICAL SPECIFICATIONS
AS THE STANDARD MODELS.

SS-206T

SS-206T

SS-206T

RATING

GAUGE

FIELD

TEMP.

WIRING

PHASE

AMPS

WATTS

VOLTS

MODEL

ELECTRICAL

WELLS/BLOOMFIELD * VERDI, NV

MODELS SS-206T (TD)

BUILT-IN (TOP MOUNT) 

INSTALLATION INSTRUCTIONS

44244-1   REV (A)

INSTALLATION INSTRUCTIONS

RECTANGULAR FOOD WARMERS

 POWER SUPPLY LEADS

1/2 IN DRAIN NPT
(SS-206TD ONLY)

2 PL

12 3/4

(324)

20 3/4

(527)

5 3/16

(132)

7/8

(22)

12

(305)

20

(508)

21 3/4

(552)

13 11/16

(348)

8 11/16

(221)

11/64

(4)

1/2

(13)

13/32

(10)

1 3/4

(44)

2 1/32

(52)

3 1/8

(79)

4 15/16

(125)

FRONT PANEL CUTOUT

TOP CUTOUT

INCHES

(MM)

NOTE: DEPENDING ON THE INSTALLATION,
CLEARANCES CAN BE CHANGED UPONFURTHER 
EVALUATIONS TO UL STANDARDS.