SERVICING INSTRUCTIONS (continued)
15
REPLACE SOLENOID
Symptom: Brewer will not flow water; or, brewer drips
continuously from brew head.
NOTE: Wrench p/n 86660 is designed to allow easy removal of
flare nuts from the water inlet fitting
IMPORTANT: Shut-off water to brewer and disconnect brewer
from electric power before removing hoses or wiring.
Remove water supply flare fitting:
a. Slide the 5/8" end of the wrench over the flats on the
inlet fitting of the valve.
b. Hold the wrench to prevent the inlet fitting from turning
while installing or removing the inlet water supply flare
nut.
Remove fill tubing:
Disconnect wiring.
Remove two screws holding solenoid to access door.
Reassemble in reverse order.
CLEAN SOLENOID SCREEN
Symptom: Automatic brewer will not flow water.
Disconnect brewer from electric power. Turn
OFF
and disconnect
water supply from brewer inlet fitting.
Unscrew water inlet fitting from solenoid.
Using needle-nose pliers, withdraw strainer screen from solenoid.
Clean screen under faucet. A stiff bristle brush may be used if
necessary.
Reinsert screen in solenoid. Be careful to maintain correct
orientation. (The
OPEN END
of the screen goes in
FIRST
.)
Reassemble in reverse order.
Fig. 11 Clean Strainer Screen
Fig. 10 Wrench #86660
Содержание Horizon 0420
Страница 20: ...0420 EXPLODED VIEW PARTS LIST 18 CABINET ELECTRICAL COMPONENTS...
Страница 21: ...0420 EXPLODED VIEW PARTS LIST continued 19 PLUMBING COMPONENTS...
Страница 23: ...21 WIRING DIAGRAM...