INSTALLATION (continued) 

NOTE:

  This equipment must  

be installed to comply with all         
applicable federal, state and  
local plumbing codes and       
ordinances. 

NSF requires 4" legs for cleaning underneath unit.  A flex line or 
loops of copper tubing from water supply should be used if the 
unit will be moved. See Figure 2 below. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
The DRIP TRAY pan is equipped with a drain outlet.   
Bloomfield recommends that this drain outlet be connected to 
1/2" I.D.  flexible tubing and routed to a building drain.  If a drain 
line is not used, the supplied plug on the pan drain fitting must 
remain in place. 

Fig. 2a Water Supply Installation - Cold Water

 

Fig. 3 Drain Line Connection

 

Fig. 2b Water Supply Installation - Hot Water

 

Содержание 9461KFT

Страница 1: ...NITED STATES OF AMERICA 724 OWNERS MANUAL for SOLUBLE COFFEE DISPENSERS MODEL 9461KFT Includes Installation Operation Use Care Servicing Instructions Model 9461 Dispenser p n 76948 Rev C ECN 12743 M72...

Страница 2: ...coffee carry a 90 days parts warranty only excludes decanters THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHAN...

Страница 3: ...rmation needed to properly install this appliance and to use care for and maintain or repair the appliance in a manner which will ensure its optimum performance WARRANTY STATEMENT xi SPECIFICATIONS 1...

Страница 4: ...ITCH 28 UPPER MIXING CHAMBER 2 ea 12 POWER CORD NEMA 5 15P 120V 15A 29 LOWER MIXING CHAMBER 2 ea 13 HEATER ON OFF SWITCH 30 POWDER DISPENSING ELBOW 2 ea 16 HOT WATER DISPENSE TUBE 35 FLIP DOWN CUP GRI...

Страница 5: ...s appliance is intended for use in commercial establishments where all operators are familiar with the appliance use limitations and associated hazards Operating instructions and warnings must be read...

Страница 6: ...ge pressure between 20 PSI and 90 PSI If your water pressure exceeds 90 PSI at anytime a pressure regulator must be installed in the water supply line to limit the pressure to not more than 90 PSI in...

Страница 7: ...er supply should be used if the unit will be moved See Figure 2 below The DRIP TRAY pan is equipped with a drain outlet Bloomfield recommends that this drain outlet be connected to 1 2 I D flexible tu...

Страница 8: ...ct canisters yet Place a container under a dispense nozzle and flow water until all air is purged from the valves and lines Repeat for each of the three nozzles Be sure drip pan drip tray is properly...

Страница 9: ...ss the SERVE SANITIZE switch to SERVE Fill PRODUCT CANISTERS with the appropriate product Left large canister Regular Coffee Right small canister Decaf Coffee Install PRODUCT CANISTERS on the CANISTER...

Страница 10: ...and LOWER MIXING CHAMBERS for condition and proper assembly 5 Visually inspect PRODUCT CANISTERS for condition Refill as necessary 6 Press the SERVE SANITIZE SWITCH to SERVE 7 Close all panels Proced...

Страница 11: ...t bristle brush Rinse with clear water 10 Remove CANISTER SHELF Wipe VACUUM CHAMBER and underside of shelf Reinstall shelf 11 Wipe interior and exterior of dispenser with a clean cloth dampened with w...

Страница 12: ...water Drain thoroughly and allow to air dry 6 Reassemble CANISTERS 7 Install POWDER DISPENSE ELBOWS on canisters Fill PRODUCT CANISTERS with the appropriate product Left hopper Regular Coffee Right h...

Страница 13: ...ce power light Not ready light does not go off water is at desired temperature Dispense thermostat set too high Set to desired temperature No product dispensed Canister empty Refill canister Serve san...

Страница 14: ...y remove panel 33 to access water valves Position panel out of the way Be careful not to damage fan or connecting wires attached to panel 3 Set the SERVE SANITIZE SWITCH to SANITIZE 4 Pull and hold a...

Страница 15: ...ixing assembly 6 Set SOLENOID SWITCH to OFF This allows the auger motor to run without dispensing water 7 Activate the dispense for an amount of time noted in step 3 8 Weigh the dispensed powder The r...

Страница 16: ...se the handle to stop the flow and enter this volume into memory This process may be repeated any number of times until the exact desired volume is achieved 6 Repeat for all valves to be set 7 Turn di...

Страница 17: ...build up Rinse with clean water and drain 7 Reinstall tank lid assembly Verify that all internal components of the dispenser are dry then reinstall the top panel 8 Reconnect dispenser to electrical s...

Страница 18: ...EXPLODED VIEW PARTS LIST 16 9461 SOLUBLE COFFEE DISPENSER...

Страница 19: ...EXPLODED VIEW PARTS LIST continued 17...

Страница 20: ...EXPLODED VIEW PARTS LIST continued 18 TANK ASSEMBLY...

Страница 21: ...EXPLODED VIEW PARTS LIST continued 19 DISPENSE SWITCH ASSEMBLY WATER INLET SOLENOID DOOR ASSEMBLY...

Страница 22: ...WIRING DIAGRAM 20 9461KFT...

Страница 23: ...NOTES 21...

Страница 24: ...TED STATES OF AMERICA Bloomfield Industries Inc Division of Carrier Commercial Refrigeration In US and Canada Telephone 775 698 5700 Fax 888 492 2783 Fax 800 356 5142 website www wellsbloomfield com f...