Bloomfield 9461KFT Скачать руководство пользователя страница 5

PRECAUTIONS AND GENERAL INFORMATION 

WARNING:

  Electric Shock Hazard 

All servicing requiring access to non-insulated components must be performed by qualified 
service personnel.  Do not open any access panels which require the use of tools.  Failure to 
heed this warning can result in electrical shock. 

 

WARNING:

  Injury Hazard 

All installation procedures must be performed by qualified personnel with full knowledge of all 
applicable electrical and plumbing codes.  Failure could result in property damage and 
personal injury. 
 

WARNING Electric Shock Hazard 

Appliance must be properly grounded to prevent possible shock hazard.  DO NOT assume a 
plumbing line will provide such a ground.  Electrical shock will cause death or serious Injury. 

 

WARNING:

  Burn Hazard 

This appliance dispenses very hot liquid.  Serious bodily injury from scalding can occur from 
contact with dispensed liquids. 

This appliance is intended for commercial use only. 

 
This appliance is intended for use to dispense beverage       
products for human consumption.  No other use is recommended 
or authorized by the manufacturer or its agents. 

 
This appliance is intended for use in commercial establishments, 
where all operators are familiar with the appliance use,  
limitations and associated hazards.  Operating instructions and 
warnings must be read and understood by all operators and  
users. 

 
Except as noted, this piece of equipment is made in the USA and 
has American sizes on hardware.  All metric conversions are   
approximate and can vary in size. 

 
The following trouble shooting, component views and parts lists 
are included for general reference, and are intended for use by 
qualified service personnel. 

 
This manual should be considered a permanent part of this 
appliance.  The manual must remain with the appliance if it is 
sold or moved to another location. 
 

This dispenser is          and 

      

   listed under UL file E9253. 

 

 
This dispenser meets 

      

 Standard 4 only when installed,        

operated and maintained in accordance with the enclosed        

instructions. 

CAUTION:

  

Equipment 

Electrical Damage 

 

DO NOT plug in or energize this 
appliance until all 

Installation     

Instructions 

are read and followed.  

Damage to the Brewer will occur if 
these instructions are not followed. 

 

CAUTION:   
Burn Hazard  
 

Exposed surfaces of the appliance 
and any container used to hold the 
dispensed liquid may be HOT to 
the touch, and can cause serious 
burns. 

E9253

E9253

STD 4

AGENCY LISTING INFORMATION 

Содержание 9461KFT

Страница 1: ...NITED STATES OF AMERICA 724 OWNERS MANUAL for SOLUBLE COFFEE DISPENSERS MODEL 9461KFT Includes Installation Operation Use Care Servicing Instructions Model 9461 Dispenser p n 76948 Rev C ECN 12743 M72...

Страница 2: ...coffee carry a 90 days parts warranty only excludes decanters THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHAN...

Страница 3: ...rmation needed to properly install this appliance and to use care for and maintain or repair the appliance in a manner which will ensure its optimum performance WARRANTY STATEMENT xi SPECIFICATIONS 1...

Страница 4: ...ITCH 28 UPPER MIXING CHAMBER 2 ea 12 POWER CORD NEMA 5 15P 120V 15A 29 LOWER MIXING CHAMBER 2 ea 13 HEATER ON OFF SWITCH 30 POWDER DISPENSING ELBOW 2 ea 16 HOT WATER DISPENSE TUBE 35 FLIP DOWN CUP GRI...

Страница 5: ...s appliance is intended for use in commercial establishments where all operators are familiar with the appliance use limitations and associated hazards Operating instructions and warnings must be read...

Страница 6: ...ge pressure between 20 PSI and 90 PSI If your water pressure exceeds 90 PSI at anytime a pressure regulator must be installed in the water supply line to limit the pressure to not more than 90 PSI in...

Страница 7: ...er supply should be used if the unit will be moved See Figure 2 below The DRIP TRAY pan is equipped with a drain outlet Bloomfield recommends that this drain outlet be connected to 1 2 I D flexible tu...

Страница 8: ...ct canisters yet Place a container under a dispense nozzle and flow water until all air is purged from the valves and lines Repeat for each of the three nozzles Be sure drip pan drip tray is properly...

Страница 9: ...ss the SERVE SANITIZE switch to SERVE Fill PRODUCT CANISTERS with the appropriate product Left large canister Regular Coffee Right small canister Decaf Coffee Install PRODUCT CANISTERS on the CANISTER...

Страница 10: ...and LOWER MIXING CHAMBERS for condition and proper assembly 5 Visually inspect PRODUCT CANISTERS for condition Refill as necessary 6 Press the SERVE SANITIZE SWITCH to SERVE 7 Close all panels Proced...

Страница 11: ...t bristle brush Rinse with clear water 10 Remove CANISTER SHELF Wipe VACUUM CHAMBER and underside of shelf Reinstall shelf 11 Wipe interior and exterior of dispenser with a clean cloth dampened with w...

Страница 12: ...water Drain thoroughly and allow to air dry 6 Reassemble CANISTERS 7 Install POWDER DISPENSE ELBOWS on canisters Fill PRODUCT CANISTERS with the appropriate product Left hopper Regular Coffee Right h...

Страница 13: ...ce power light Not ready light does not go off water is at desired temperature Dispense thermostat set too high Set to desired temperature No product dispensed Canister empty Refill canister Serve san...

Страница 14: ...y remove panel 33 to access water valves Position panel out of the way Be careful not to damage fan or connecting wires attached to panel 3 Set the SERVE SANITIZE SWITCH to SANITIZE 4 Pull and hold a...

Страница 15: ...ixing assembly 6 Set SOLENOID SWITCH to OFF This allows the auger motor to run without dispensing water 7 Activate the dispense for an amount of time noted in step 3 8 Weigh the dispensed powder The r...

Страница 16: ...se the handle to stop the flow and enter this volume into memory This process may be repeated any number of times until the exact desired volume is achieved 6 Repeat for all valves to be set 7 Turn di...

Страница 17: ...build up Rinse with clean water and drain 7 Reinstall tank lid assembly Verify that all internal components of the dispenser are dry then reinstall the top panel 8 Reconnect dispenser to electrical s...

Страница 18: ...EXPLODED VIEW PARTS LIST 16 9461 SOLUBLE COFFEE DISPENSER...

Страница 19: ...EXPLODED VIEW PARTS LIST continued 17...

Страница 20: ...EXPLODED VIEW PARTS LIST continued 18 TANK ASSEMBLY...

Страница 21: ...EXPLODED VIEW PARTS LIST continued 19 DISPENSE SWITCH ASSEMBLY WATER INLET SOLENOID DOOR ASSEMBLY...

Страница 22: ...WIRING DIAGRAM 20 9461KFT...

Страница 23: ...NOTES 21...

Страница 24: ...TED STATES OF AMERICA Bloomfield Industries Inc Division of Carrier Commercial Refrigeration In US and Canada Telephone 775 698 5700 Fax 888 492 2783 Fax 800 356 5142 website www wellsbloomfield com f...

Отзывы: