background image

671EX  p/n 2M-76624  9221EX Dual Satellite Owmers Manual

22

WIRING DIAGRAM

3NAC

VOL

TS

380-415

MODEL

9221EX

W

A

TTS

6250

L1

8.7

L2

8.7

L3

9.8

AMPS

N

1.1

HZ

50/60

18

RED

36

BLUE

BLUE

35

34

BROWN

BLACK

1

1

ORANGE

39

GREEN/YELLOW

LIQUID

LEVEL PROBE

BLUE

27

SWITCH

HEA

TER

LIGHT

BREW

RED

RED

 T

ANK

GROUND

LIQUID

LEVEL

INLET V

AL

VE

19

INPUT

NO

COM

MAX

NC

BOARD

BROWN

WHITE

38

JUMPER

L1

WIRE L2

LOAD

LEFT TIMER

YELLOW

RIGHT TIMER

LOAD

WIRE L2

L1

   L

EFT

 W

ARMER

 ELEMENT

240V

, 100W

WHITE

37

29

BLUE

10

BLACK 12GA

WHITE

12

RED 12GA

9

8

BLUE 12GA

14

WHITE

BLUE

33

BLUE

32

L3

L2

L1

L3

L2

L1

    U

PPER

TERMINAL

 

BLOCK

N

L3

L2

L1

BLACK

BLACK

22

35

BLACK

WHITE

BLUE

25

WHITE

20

WHITE

20

RED

18

WHITE

14

WHITE

38

   RIGHT

DUMP

 V

AL

VE

   L

EFT

DUMP

 

V

AL

VE

HTG ELEMENT

230V 6000W

1

2

3

4

N

L3

L2

L1

HI-LIMIT

THERMOST

A

T

THERMOSTA

T

R. ST

OP

 BREW SWITCH

R. VOLUME  SELECT

 SWITCH

21

BLACK

23

BLACK

23

BLUE

26

BLUE

28

WHITE

WHITE

20

21

21

22

22

23

R. ST

AR

T

  BREW  SWITCH

L. VOLUME

 SELECT

 SWITCH

L. ST

AR

T

  BREW

 SWITCH

L. ST

OP

 BREW

SWITCH

BLUE

24

YELLOW

BLACK

23

WHITE

14

BLACK

1G

1 1/2G

1 1/2G

1G

    L

OWER

TERMINAL

 BLOCK

BLACK

17

16

15

WHITE

37

     L

EFT

W

ARMER 

SWITCH

    R

IGHT

W

ARMER 

SWITCH

  RIGHT  W

ARMER

 ELEMENT

240V

, 100W

BLUE

ORANGE

BLACK

17

5

BLUE 12GA

6

RED 12GA

BLACK 12GA

7

CONT

ACT

OR

    #

2

CONT

ACT

OR

    #

1

1

BROWN 12GA

BLACK 12GA

4

3

RED 12GA

BLUE 12GA

2

4

1

5

2

6

3

SWITCH

POWER

240V

240V

FUSE 2

FUSE 1

T1

T2

T3

L1

L2

L3

L3

L2

L1

T3

T2

T1

13

31

WHITE

BLUE

30

2M-76656 ISSUE (A)

Содержание 9221EX

Страница 1: ...OMFIELD INDUSTRIES p n 2M 76624 Rev C M671EX 120813 671EX OWNERS MANUAL for SS2 SERIES DUAL SATELLITE COFFEE BREWERS with ELECTRO MECHANICAL CONTROL and EXTERNALLY HEATED SATELLITE SERVERS MODEL 9221E...

Страница 2: ...a 30 day parts warranty only b dispensers i e tea and coffee carry a 90 days parts warranty only excludes decanters THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN LIEU OF ANY OTHER WARRANTIES EXPRESS...

Страница 3: ...T xi SPECIFICATIONS 1 FEATURES OPERATING CONTROLS 2 PRECAUTIONS GENERAL INFORMATION 4 AGENCY APPROVAL INFORMATION 4 INSTALLATION 5 OPERATION 7 CLEANING INSTRUCTIONS 10 PROGRAMMING INSTRUCTIONS 12 TROU...

Страница 4: ...SWITCH BYPASS NOZZLE LEFT BREWING CONTROLS ADJUSTABLE LEG BREW CHAMBER IN POSITION SATELLITE IN POSITION POWER SWITCH located on back CONTROL PANEL see below READY TO BREW INDICATOR CONTROL PANEL FUSE...

Страница 5: ...dispensed here Lists manufacturer model and serial number Also lists voltage and wattage rating of brewer Glows when the tank water is up to temperature Located on lower right rear of brewer Turns ma...

Страница 6: ...wiring Any procedure which requires the use of tools must be performed by a qualified technician This manual is considered to be a permanent part of the appliance This manual and all supplied instruc...

Страница 7: ...iameter copper tubing for installations of 12 4 meters or less and not less than 3 8 10 mm I d copper tubing for installations exceeding 12 4 meters Brewer must be connected to a COLD water line NOTE...

Страница 8: ...ation close proximity to the appliance by a licensed electrician Refer to General Layout Data sheet for electrical ratings SUPPLY CORDS Power supply cords should be oil resistant sheathed flexible cab...

Страница 9: ...plumbing connections are secure and leak proof 1 CHECK BREWER FOR PROPER CONFIGURATION Make sure spray disk gaskets are in place INSIDE of spray heads Make sure spray disks are properly installed Che...

Страница 10: ...erly installed Verify that the gaskets are properly installed inside the spray heads Check the brew chambers Check that the brew chamber is clean Check that the bypass diverters are properly installed...

Страница 11: ...lume Press VOLUME SELECT switch to 1 GAL or 1 1 2 GAL Start the Brew Press either the right or left START BREW key NOTE The brew can be cancelled at any time by pressing the BREW STOP key At the end o...

Страница 12: ...ets from spray heads 5 Wipe inside of spray head and area around spray head with a soft clean cloth or sponge moistened with clean water 6 Wash spray disks in a sink using warm water and a mild deterg...

Страница 13: ...n on ears on sight glass guard Then pull ears forward Lift guard off of retaining clip b Remove sight glass tube from silicone elbow Run the sight glass brush through the tube at least ten times c Rea...

Страница 14: ...ly 2 Remove the brewer top panel then remove the tank lid assembly Do not disconnect the tank assembly at this time 3 Siphon all water from the hot water tank 4 Mix 10 gallons of deliming solution acc...

Страница 15: ...up Reinstall gaskets and spray disks 13 Reconnect brewer to electrical supply 14 Install the brew chamber without filter paper or grounds 15 Place an empty satellite under the brew chamber Run at leas...

Страница 16: ...r other container to calibrate volume 1 Press HEATER ON OFF switch to OFF Turn POWER switch on back of brewer OFF 2 Remove TOP PANEL Operating controls are accessible through the top panel only 3 Adju...

Страница 17: ...he top panel only 3 Remove one of the plugs in the tank cover and insert a thermometer of known accuracy 4 Locate the CONTROL THERMOSTAT on the right side of the top housing Turn CLOCKWISE to increase...

Страница 18: ...ermostat Brew chamber overflows Too many paper filters or wrong filter used Use one genuine Bloomfield paper filter per brew Chamber discharge hole plugged Clean brew chamber Timer not set properly Se...

Страница 19: ...FAUCET GUARD 4 2U 76577 1 FAUCET SHANK ASY 4 1 2V Z15411 1 FAUCET ESP ULTEM HI TEMP 4 2 2U 71460 1 SEAT CUP TEA DISP FAUCET 4 3 WS 84393 1 HANDLE FAUCET 4 4 2C 84393 1 HEX NUT SPOUT VALVE 4 5 2C H201...

Страница 20: ...IOR COMPONENTS 18 IL2520 Rev 8 10 12 47 51 50 3 49 48 44 13 14 34 26 18 34 32 34 25 34 34 27 31 8 11 2 33 45 29 43 12 5 15 16 1 34 28 20 22 23 19 17 30 41 21 10 21 53 34 54 2 PL 9 34 52 2 PL 4 24 46 6...

Страница 21: ...24 2E 72936 SWITCH ROCKER ON OFF 125 1 25 D7 76573 HOUSING LOWER 1 26 D7 76589 COVER TOP HOUSING 1 27 D7 76587 PANEL FRONT 1 28 D7 76626 PLATE BOTTOM ASSY 1 29 D7 76625 BASE WRAP 1 30 2P 75123 TIMER...

Страница 22: ...Manual EXPLODED VIEW INTERIOR COMPONENTS 20 17 23 2 35 13 11 12 32 2 5 21 24 10 28 19 33 34 35 36 37 43 38 39 26 15 27 29 30 31 39 42 40 4 41 22 MODEL 9221EX EXPLODED VIEW Part 2 8 3 18 2 19 7 16 18 1...

Страница 23: ...RAY HEAD 2 3 8 LG 4 20 A6 73537 TUBE SIL 312 ID X 9 LG 1 21 2V 74619 VALVE ADJUST WATER OUTLET 2 22 2C 72148 WASHER LOCK 1 2 ID INT SE 1 23 2C 35485 NUT 1 4 20 HEX FINISHED S 4 24 2C 76007 SCREW 8AX1...

Страница 24: ...ACK BLACK 22 35 BLACK WHITE BLUE 25 WHITE 20 WHITE 20 RED 18 WHITE 14 WHITE 38 RIGHT DUMP VALVE LEFT DUMP VALVE HTG ELEMENT 230V 6000W 1 2 3 4 N L3 L2 L1 HI LIMIT THERMOSTAT THERMOSTAT R STOP BREW SWI...

Страница 25: ...ypass channel The remainder of the brew water is discharged through the SPRAY DISK and flows over the grounds in the brew basket Each half of the brewer is independently controlled HOT WATER FAUCET Th...