INSTALLATION INSTRUCTIONS (continued)
NOTE:
This equipment must be
installed to comply with
applicable federal, state and
local plumbing codes and
ordinances.
WARNING ELECTRIC
SHOCK HAZARD:
Brewer must be properly
grounded to prevent possible
shock hazard. DO NOT
assume a plumbing line will
provide such a ground.
Electrical shock will cause death
or serious injury.
IMPORTANT:
Do not connect
brewer to electrical power until
both tanks are filled with water.
Pour water into each pour-over
opening until water flows from
the respective brew head.
IMPORTANT:
Supply power must match
nameplate for voltage and
phase. Connecting to the
wrong voltage will damage the
brewer or result in decreased
performance. Such damage is
not covered by warranty.
NSF requires that the brewer be able to be moved for cleaning
underneath. A flex line or loops of copper tubing will satisfy this
requirement. See Figure 2 below.
In some areas, local codes require a backflow preventer (check
valve) to be installed on the inlet water line. If a backflow
preventer is used, you must install a
water hammer arrester
in
the incoming line, between the backflow preventer and the
brewer inlet, as far away from the brewer as space will allow.
This will relieve the excessive back pressures that can cause
faucet leaks and solenoid malfunctions.
ELECTRICIAN’S INSTALLATION INSTRUCTIONS
REFER TO ELECTRICAL SPECIFICATIONS - Page 1
Check the nameplate to determine correct electrical service
required for the Brewer to be installed.
IMPORTANT:
Before connecting to electricity, make sure
automatic brewers are connected to the water supply.
Gourmet 1000™ dual brewers
must be wired by an electrician.
Model 8792 requires a 120/240V 20A circuit (50/60 Hz, L1, L2,
Neut. plus Ground).
Remove front panel to gain access to terminal block. Green
terminal must be connected to a suitable building ground. Circuit
must be capable of 4000 Watts. See figure 3 at right.
IMPORTANT:
Wiring must be installed in approved solid or
flexible conduit, and must be secured to the brewer with a strain
relief (to be provided by the installer).
Fig. 3 115/230 Volt Terminal Block
Fig. 2 Water Supply Installation
5
625
75873
Owner
s M
anual G
ourmet
1000 Dual
Airpo
t Br
ewers