4 NeXgen Platform Base
Quick Guide
Step 3: Connecting to a PC/Laptop
ETHERNET ACCESS:
Local or remote communication with the unit is only possible through a GUI-based menu via any standard web browser.
Before you can communicate with the unit, you must configure your computer's IP address to be in the same subnet as the
units default IP address. To do so, follow these steps:
Plug one end of the Ethernet cable into
Port 1
on the NeXgen Gateway Master Controller front-panel interface. Plug
the other end of the Ethernet cable to your computer.
The factory default IP address of the NeXgen Master Controller management port is
172.16.70.1
. To be able to
communicate with the NeXgen Master Controller management port, you must first change your computer's IP address.
1
2
The following steps explain how to do this for a computer with Windows 7
,
Windows 8.x
or
Windows 10 operating software:
(a) On your computer, navigate to the “Network and Sharing Center”.
(Note: Can be found using the search box in the Start Menu or for Windows 8.x, the Start Screen)
(b) Once open, click on “Change Adapter Settings” on left hand side of the window.
(c) Right-click on the “Local Area Connection”, and then click on the “Properties”.
(d) A dialog box entitled “Local Area Connection Properties” will appear. In this box, double-click on the “Internet
Protocol Version 4 (TCP/IPv4)”.
(e) A dialog box entitled ”Internet Protocol Version 4 (TCP/IPv4) Properties” will appear. Select the “Use the following
IP address” option and enter the following addresses:
IP address:
172.16.70.2
Subnet mask:
255.255.255.0
No need to enter a value for the Default Gateway.
Click OK to close the dialog box. Your computer is now ready to communicate with the unit.
Step 2: Installing the Controller and Power Supplies (continued)
REMINDER
Before NXG-CCQD-24 module installation, don't forget to insert the CableCARDs into the
module. Please see the NXG-CCQD-24 Manual for more information on installation.
IMPORTANT
The Master Controller (MC) module MUST be installed in the empty slot as directed in #2.
The system will not work if the MC module is installed into any other slot.
Install the Master Controller (sold separately) by sliding the module into the card slot on the far left within the chassis.
2
3
Install the appropriate input and output modules for your NeXgen application in any of the 12 slots. When possible
space the input and output modules apart to maximize airflow.