43
POwEr SuPPly (MaINS) aND
BaTTEry cHarGE (cHrG) lED STaTuS
INSTRUMENT
CONNECTED
TO THE MAINS
POWER SUPPLY
LED MAINS
LED BATT CHRG
NOTES
OFF
NO
OFF
OFF
Batteries sufficiently charged
ON
NO
OFF
OFF
Battery operation
OFF
NO
OFF
Flashing
2 SECONDS OFF
0.5 SECONDS ON
The meter does not turn on.
Recharge the batteries.
OFF
YES
ON
Flashing
0.5 SECONDS OFF
0.5 SECONDS ON
Abnormal battery temperature.
The recharge cycle has been suspended
temporarily and will automatically reset.
OFF
YES
ON
ON
Batteries in fast charge
OFF
YES
ON
OFF
Battery charge completed
OFF
WITH A POWER
SUPPLY NOT FROM
BLONDER TONGUE
Flashing
0.5 SECONDS OFF
0.5 SECONDS ON
OFF
The meter does not turn on.
Check the mains power adapter
turning ON
NO or YES
FLASHES
15 TIMES
OFF
The meter is being turned on
ON
NO or YES
FLASHING SIMULTANEOUSLY
0.5 SECONDS OFF - 0.5 SECONDS ON
The meter detects an error
and turns off automatically.
ON
YES
FLASHING ALTERNATIVELY
1 SECOND OFF - 1 SECOND ON
BATTERY TEST being carried out.
The meter charges and discharges the
batteries AUTOMATICALLY