EN
7
7
Mounting the hood body
• Before attaching the hood body, tighten the two
screws Vr located on the hood body mounting points.
• Hook the hood body onto the screws 12a.
• Fully tighten the support screws 12a.
• Adjust the screws Vr to level the hood body.
12a
Vr
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to
the chimney using either a flexible or rigid pipe ø 150
or 120 mm, the choice of which is left to the installer.
• To install a ø 120 mm air exhaust connection, insert
the reducer flange 9 on the hood body outlet.
• Fix the pipe in position using sufficient pipe clamps
(not supplied).
• Remove possible charcoal filters.
9
ø 120
ø 150
RECIRCULATION VERSION AIR OUTLET
• Push fit connection 15 onto the hood body outlet.
• Insert the connection extension pieces laterally 14.1
in connection 15.
• Make sure that the outlet of the extension pieces 14.1
is horizontally and vertically aligned with the chim-
ney outlets. If this is not the case, adjust the position
by either reversing the connection extension pieces
14.1 and then reassemble as described previously.
• Ensure that the activated charcoal filters have been
inserted.
14.1
15