7
WARNING: ELECTRICAL GROUNDING INSTRUCTIONS
This appliance is equipped with a three-prong (grounding) plug for
your protection against shock hazard and should be plugged directly
into a properly grounded three-prong receptacle. Do not cut or
remove the grounding prong from this plug. (120V units only).
WIRING DIAGRAM FOR APPLIANCE IS LOCATED INSIDE CABINET DOOR.
EXHAUST FANS AND CANOPIES:
Canopies are set over ranges, ovens, kettles, etc., for ventilation purposes. It is
recommended that a canopy extend 6 inches past the appliance and be located 6 feet 6
inches from the floor. Filters should be installed at an angle of 45 degrees or more with
the horizontal. This position prevents dripping of grease and facilitates collecting the
run-off grease in a drip pan, usually installed with the filter. A strong exhaust fan tends
to create a vacuum in the room and may interfere with burner performance or may
extinguish pilot flames. Makeup air openings approximately equal to the fan area will
relieve such vacuum. In case of unsatisfactory performance on an appliance, check with
the exhaust fan in the “OFF” position.