Installation
14
Initial Startup
NOTE: This procedure is for gas models only.
The following is a checkĆlist to be completed by
qualified personnel prior to turning on the
appliance for the first time.
j
Remove the side panel.
j
Turn the manual shutĆoff valve, located on the
front of the oven, to the ON position.
j
Turn the mode switch to Cook, and set the
thermostat to 500
_
F (260
_
C).
With the main burner on, check the following.
j
Verify there are no gas leaks, by checking all
gas connections with a soapy water solution.
j
Verify that the manifold pressure is as recomĆ
mended. The manifold pressure can be
checked at the PRESSURE TAP located on
the burner manifold.
j
If the manifold pressure reading is set to the
recommended pressure requirements, allow
the oven to burnĆoff for 2 hours. If the pressure
reading is not set correctly, turn off the oven
and readjust accordingly.
WARNING
The break in procedure burns off excess
oils present in the metals during fabricaĆ
tion. Smoke may be produced. Proper
ventilation is required.
ADJUSTMENTS ASSOCIATED WITH INITIAL
INSTALLATION
Each oven, and its component parts, have been
thoroughly tested and inspected prior to shipĆ
ment. However, it is often necessary to further
test or adjust the oven as part of a normal and
proper installation. These adjustments are the
responsibility of the installer, or dealer. Since
these adjustments are not considered defects
in material or workmanship, they are not covĆ
ered by the Original Equipment Warranty. They
include, but are not limited to:
D
calibration of the thermostat
D
adjustment of the doors
D
burner adjustments (gas ovens only)
D
leveling
D
testing of gas pressure (gas ovens only)
D
tightening of fasteners.
No installation should be considered complete
without proper inspection, and if necessary,
adjustment by qualified installation or service
personnel.