background image

20 

OM-KTT/KTC-G

Maintenance

19.   Removal of water level probe

a.  

Tilt kettle 90° and remove bottom cover.

b.  

Remove yellow wire from probe.

c.  

Unscrew probe from kettle jacket.

20.   Installation of water probe

a.  

Apply Teflon tape to probe threads.

b.  

Screw probe into kettle jacket and torque to 150 in-lbs.

c.  

Attach yellow wire to probe.

d.  

Reinstall bottom cover.

e.  

Check water level.

f.  

Remove air from jacket.

21.   Removal of pressure switch

a.  

Tilt kettle a full 90°.

b.  

Remove bottom cover.

c.  

Unplug red and white wires from switch.

d.  

Using a 9/16 open end wrench, carefully unscrew the pressure 

switch from the 90° elbow.

22.   Installation of pressure switch

a.  

Hand start the pressure switch into the 90° elbow.

b.  

Using a 9/16 wrench, tighten the switch to 90 in-lbs.

c.  

Reattach the red and white wires to the switch.

d.  

Reinstall bottom cover.

e.  

Check water level.

f.  

Remove air from jacket.

Содержание 10G-KTC

Страница 1: ...www blodgett com 44 Lakeside Avenue Burlington Vermont 05401 USA Manufacture Service Questions 866 518 3977 PART NUMBER 170081 REV A 04 11 KTT KTC G Series GAS TABLE TOP TILTING KETTLE INSTALLATION O...

Страница 2: ...orized service agent Evacuate all personnel from the area WARNING Improperinstallation adjustment alteration serviceormaintenancecan cause property damage injury or death Read the installation operati...

Страница 3: ...DO NOT OVERFILL THE KETTLE WHEN COOKING HOLDING OR CLEANING KEEP LIQUIDS A MINIMUM OF 2 3 5 8 CM BELOW THE KETTLE BODY RIM TO ALLOW CLEARANCE FOR STIRRING BOILING AND SAFE TRANSFER OF PRODUCT CAUTION...

Страница 4: ...ER THAN THOSE SUPPLIED BY THE MANUFACTURER OR AUTHORIZED DISTRIBUTORS CAN CAUSE INJURY TO THE OPERATOR AND DAMAGE TO THE EQUIPMENT AND WILL VOID ALL WARRANTIES WARNING KEEP AREA AROUND KETTLE FREE AND...

Страница 5: ...INTERNATIONAL 8501 East Pleasant Valley Road Cleveland Ohio 44131 NSF INTERNATIONAL 798 N Dixboro Rd P O Box 130140 Ann Arbor Michigan 48113 0140 UNDERWRITERS LABORATORIES INC 333 Pfingsten Road North...

Страница 6: ...re the same as the above with the exception of the crank tilt hand wheel The gas supply shuts off automatically when the kettle is tilted The unit must be specified for use with natural gas or propane...

Страница 7: ...top of the Service Log on Page 33 Keep this manual with the unit To remove the kettle from the box cut any straps from around the box Detach the box sides from the skid Pull the box up off the unit t...

Страница 8: ...Z223 1 latest edition National Fuel Gas Code The kettle should be installed in an adequately ventilated room with provision for adequate air supply The best ventilation will employ a vent hood and ex...

Страница 9: ...it is anchored to a mounting surface apply a small bead of silicone caulk around the perimeter of the kettle base and seal the joint 11 Make sure the water level is correct in the jacket by confirming...

Страница 10: ...s been installed the installer should test to ensure that it is operating correctly 1 Remove literature and packing materials from inside and outside of the unit 2 Add water to the kettle to a depth o...

Страница 11: ...the toggle switch to ON f Turn the thermostat to the desired heat setting 2 To Stop Kettle Heating a To tilt the body of the kettle forward turn the hand crank on the front of the cabinet counter cloc...

Страница 12: ...keeping kettle body in a tilted position or SLOWLY returning the kettle body to an upright position 6 Use of Common Accessories Lift Off Cover a As with stock pot cooking an optional lift off cover wi...

Страница 13: ...handling Then slowly lower product into kettle 4 When removing basket with cooked product lift basket straight up ensuring bottom of basket clears the rim and pouring lip of the kettle Wear protectiv...

Страница 14: ...n the thermostat it causes the automatic valve to admit gas to the main burner where it is ignited by the pilot flame When the kettle reaches the set temperature the thermostat switch opens This stops...

Страница 15: ...se steel wool which will leave particles in the surface and cause eventual corro sion and pitting 7 The outside of the unit may be cleaned with a warm water 100 F or less spray Do not use a high press...

Страница 16: ...it be sanitized just before use 11 Clean the kettle thoroughly If there is difficulty removing mineral de posits or a film left by hard water or food residues then use a de liming agent following manu...

Страница 17: ...release the ring and permit the valve to snap shut If the ring does not activate if there is no discharge or if the valve leaks stop using the kettle immediately and contact a authorized service repr...

Страница 18: ...r required Use only distilled water 2 Hang a strip of pH test paper on the rim of the container with about 1 inch of the strip below the surface of the water 3 Stir the water continuously while you sl...

Страница 19: ...hand side cover see Section 1 above b Remove blue and green wires from light c Remove nut from light on inside of electrical box d Pull light out being careful not to lose rubber grommet 6 Installatio...

Страница 20: ...n module and install the four mounting screws b Reinstall wiring in the following order starting on the left with terminal 1 i Red MV ii Yellow MV PV iii Black PV iv Green 24v from burner v Green 24v...

Страница 21: ...tat shroud d Tilt kettle to 90 e Remove bottom cover f Remove blue and red wires from thermostat g Unscrew temperature bulb from kettle body being careful not to damage adjacent pressure switch 18 Ins...

Страница 22: ...install bottom cover e Check water level f Remove air from jacket 21 Removal of pressure switch a Tilt kettle a full 90 b Remove bottom cover c Unplug red and white wires from switch d Using a 9 16 op...

Страница 23: ...enance section b Thermostat dial setting Auth Service Rep Only c For defective thermostat The thermostat should click when the dial is rotated to settings above and below the temperature of the kettle...

Страница 24: ...d PV MV If 24V is not present replace the ignition control module X b That gas pressure is at least 3 5 W C 8 7818 b X c Electrical connections of the main valve to terminals to a sure that they are s...

Страница 25: ...098443 5 GAS VALVE MANUAL SHUT OFF 098458 6 VALVE 1 4 SWING CHECK 096915 7 GAUGE 084208 8 KETTLE BODY ASSY 137733 9 GLASS SITE ROUND 108554 10 VALVE PRESSURE RELIEF 50 PSI 097005 11 GUARD THERMOSTAT 1...

Страница 26: ...TUBE PILOT 135487 6 PILOT ORIFICE SPUD NATU RAL GAS 098648 6 PILOT ORIFICE SPUD PRO PANE GAS 098647 7 FITTING COMPRESSION 90 NOT SHOWN 004584 8 ORIFICE SEE TABLE BELOW Model of Orifices Natural Gas P...

Страница 27: ...HER LOCK 1 4 005655 16 SCREWHEXHDCAP1 4 20X1 1 2 005649 17 NUT HEXAGON KEPS 1 4 20 012940 18 PLATE SHROUD WELD ASM 137680 19 SEAL TRUNION 137005 20 PLATE SHROUD WELD ASM 5 6 QT 137700 20 PLATE SHROUD...

Страница 28: ...05649 17 NUT HEXAGON KEPS 1 4 20 012940 18 PLATE SHROUD WELD ASM 137680 19 SEAL TRUNION 137005 20 PLATE SHROUD WELD ASM 5 6 QT 137700 20 PLATE SHROUD WELD ASM 10 12 QT 137380 21 GASKET 3 8 THK X WIDE...

Страница 29: ...02989 3 STOP MANUAL TILT 137697 4 KEY 1 4 SQ X 5 LG 137746 5 COLLAR SET 1 1 2 ID X 2 1 4 OD X 3 4 THK 003118 6 SCREW HEX HD CAP 3 8 16 X 1 1 2 005615 7 WASHER FLAT 3 8 005830 8 NUT HEX 3 8 16 005619 9...

Страница 30: ...374 3 GEAR WORM 128001 4 ASSEMBLY GEAR SECTOR 128028 5 ASSEMBLY BEARING BLOCK 128021 6 KEY 1 4 SQ X 1 LG 122371 7 RETAINING RING 1 500 124764 8 ASSEMBLY HANDWHEEL 124719 9 PIN ROLL 1 4 X 1 63 LG 12803...

Страница 31: ...Part No 1 PRESSURE SWITCH 096963 2 THERMOSTAT 012313 3 WATER LEVEL ELECTRODE 015589 4 BRACKET 137736 5 COVER NOT SHOWN 003141 6 GASKET BOTTOM COVER NOT SHOWN 137969 7 SCREW 20 X 1 NOT SHOWN 012597 8...

Страница 32: ...30 OM KTT KTC G Parts List Key Description Part No 1 GAUGE COMPOUND PRES SURE W DUAL 170003 2 VALVE PRESSURE RELIEF 50 PSI 097005 3 ASSY WATER FILL SUB 137438 4 ELBOW NPT 90 DEG STREET BLK 096905...

Страница 33: ...OLDER TYPE 3 AG 077854 7 FUSE THREE AMP TYPE 3 AG 077853 8 SCREW 6 32 X 3 8 LG FOR 6 009697 9 P C BOARD MOUNTING POST 099901 10 SCREW 8 X 3 8 LG HEX SLOT FOR 5 AND 17 069789 11 SCREW 8 32 X 1 1 4 RND...

Страница 34: ...32 OM KTT KTC G Wiring Diagram...

Страница 35: ...OM KTT KTC G 33 Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By...

Страница 36: ...PART NUMBER 170081 REV A 04 11 BLODGETT OVEN COMPANY www blodgett com 44 Lakeside Avenue Burlington Vermont 05401 USA Telephone 866 518 3977...

Отзывы: