Installation
9
Utility Connections
STEAM CONNECTION
NOTE: COSĆ8EDS and BCSĆ8DS only.
Connect the appliance to a 200 psi maximum exĆ
ternal steam source per local or state codes. The
steam must be clean, potable and fit for human
consumption. Failure to connect this appliance to
a suitable steam source will revoke the approval of
NSF.
The appliance is equipped with an internal steam
pressure regulator set at 2 psi. Verify the regulator
is set to 2 psi prior to operating the appliance.
ELECTRICAL CONNECTION
Before making any electrical connections to these
units, check that the power supply is adequate for
the voltage, amperage, and phase requirements
stated on the rating name plate mounted on the
unit.
Wiring diagrams are located on the inside of the
louvered side panel.
NOTE: DISCONNECT THE POWER SUPPLY TO
THE UNIT BEFORE SERVICING!
U.S. and Canadian installation
All units, when installed, must be electrically
grounded in accordance with local codes or in the
absence of local codes, with the
National Electrical
Code, ANSI/NFPA 70-Latest Edition and/or CanaĆ
dian Electrical Code CSA C22.1
as applicable.
General Export Installations
Installation must conform with Local and National
installation standards. Local installation codes
and/or requirements may vary. If you have any
questions regarding the proper installation and/or
operation of your unit, please contact your local
distributor. If you do not have a local distributor,
please call Blodgett Combi at 0011Ć802Ć860Ć3700.
CAUTION: on 480V units, the fan should be
checked to ensure the proper rotation after
connecting the appliance. See Figure 5. If the
fan turns in the wrong direction, the appliance
will not function properly and damage to the
unit can occur. Improper connection of the apĆ
pliance renders the warranty invalid.
Direction Of Fan Rotation
Figure 5
NOTE: ALL MANUAL RESETS SHOULD BE REĆ
STORED BEFORE CONNECTING POWER
TO THE APPLIANCE.
WARNING!!
Improper electrical installation will invaliĆ
date your warranty.