Page 11 of 19
BLOCKsignalling
www.blocksignalling.co.uk
Maximum setting 255 seconds.
Default setting (after factory reset) 5 seconds.
After the waiting time, the train departs in same direction as it arrived.
Speed Control (option 6)
Sets whether the train stops and starts using the acceleration and deceleration
settings, or simply starts and stops with full power immediately applied and removed.
1=starts and stops with full power immediately applied and removed.
2=gradual acceleration and deceleration.
Rate of Acceleration (option 7)
Sets rate of acceleration applied.
Time in seconds for the voltage applied to the track to be raised from OFF up to the
maximum set by the adjuster on the board.
A higher value results in slower acceleration.
Note: the smoothness of the acceleration is highly dependent on the model and the
amount of friction present. Sometimes a longer acceleration time will be required, as
the model will not move during the initial application of voltage to the track.
Minimum setting 1 second.
Maximum setting 20 seconds.
Default setting (after factory reset) 6 seconds.
Rate of Deceleration (option 8)
Sets rate of deceleration applied.
Numerical value is the time in seconds for the voltage applied to the track to be
lowered from the maximum set by the adjuster on the board to OFF.
Minimum setting 1 second.