MystACL™ Z Manual Rev. A  

 

 

© 2019 Blizzard Lighting, LLC

3. SETUP

Fuse Replacement

Remove the fuse holder from of its housing. Then take out the dam-

aged fuse from its holder and replace with exact same type of fuse. 

Reattach the fuse holder, and then reconnect power.

Connecting A Bunch of MystACL™ Z Fixtures

You will need a serial data link to run light shows using a DMX-512 

controller or to run shows on two or more fixtures set to sync in mas

-

ter/slave operating mode. The combined number of channels required 

by all the fixtures on a serial data link determines the number of fix

-

tures the data link can support.

Fixtures on a serial data link must be daisy chained in one single line. 

Also, connecting more than 32 fixtures on one serial data link without 

the use of a DMX optically-isolated splitter may result in deterioration 

of the digital DMX signal. The maximum recommended cable-run dis-

tance is 500 meters (1640 ft).  The maximum recommended number 

of fixtures on a serial data link is 32 fixtures.

Data/DMX Cabling

To link fixtures together you’ll need data cables.  You should use data-

grade cables that can carry a high quality signal and are less prone to 

electromagnetic interference.

For instance, Belden© 9841 meets the specifications for EIA RS-485 

applications. Standard microphone cables will “probably” be OK, but 

note that they cannot transmit DMX data as reliably over long distanc-

es.  In any event, the cable should have the following characteristics:

 

2-conductor twisted pair plus a shield

 

Maximum capacitance between conductors – 30 pF/ft.

 

Maximum capacitance between conductor & shield – 55 pF/ft.

 

Maximum resistance of 20 ohms / 1000 ft.

 

Nominal impedance 100 – 140 ohms

Before replacing the fuse, disconnect the power cord. 

ALWAYS replace it with the same type and rating.

Содержание MYSTACL Z

Страница 1: ...Blizzard Lighting LLC http www blizzardpro com Waukesha WI USA Copyright c 2019...

Страница 2: ...res 7 Data DMX Cables 7 Cable Connectors 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting up DMX Control 8 Fixture Linking Master Slave Mode 9 Mounting Rigging 9 Mounting Points 10 Clamp Mounting...

Страница 3: ...ur local power supply See the label on the fixture or refer to the fixture s specifications chart for more information A fixture s listed current rating is its average current draw under normal condit...

Страница 4: ...n slots are blocked ALWAYS disconnect from the power source before servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carr...

Страница 5: ...uick Reference 13 26 28 46 Channel Modes 13CH Basic 26CH Ext 28CH Normal 46CH P Map What It Does 1 1 1 1 Tilt 2 2 2 2 Tilt Fine 3 3 3 3 Zoom wide narrow 4 4 Set 1 Color Macros overrides set 1 R G B W...

Страница 6: ...e MystACL Z Pin Up Picture Figure 2 The Front Panel Power Output Power Input Fuse Holder Menu Buttons 5 Pin DMX In Out 3 Pin DMX In Out RJ45 In Out Power Switch LCD Display 10 30W RGBW LEDs with 3 60...

Страница 7: ...solated splitter may result in deterioration of the digital DMX signal The maximum recommended cable run dis tance is 500 meters 1640 ft The maximum recommended number of fixtures on a serial data lin...

Страница 8: ...ure s Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 Data 1 Primary Data Link Pin 2 Pin 2 Data 1 Primary Data Link Pin 3 Pin 3 Data 2 Optional Secondary Data Link Pin 4 Pin 4...

Страница 9: ...he Operating Adjustments section in this manual for com plete instructions for this type of setup and configuration Mounting Rigging This fixture may be mounted in any SAFE position provided there is...

Страница 10: ...safety inspection of all installation material and the fixture If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury Caution Plea...

Страница 11: ...le 1 Clamp 2 Omega Bracket 3 Turn Quick Lock Fasteners 2 1 Clamp Mounting This fixture provides a mounting bracket assembly that secures the bottom of the base the Omega Bracket and the safety cable r...

Страница 12: ...cending order DOWN Scrolls through menu items and numbers in descending order OK Is used to save any changes made to a menu setting LEFT To return to the previous option or menu without changing the v...

Страница 13: ...ay ON rotation of the display by 180 OFF Key Lock ON passcode Up Down Up Down OK OFF Disp Flash ON flash menu display if no signal OFF Backlight 001 050 adjust menu brightness Zoom Invert ON invert DM...

Страница 14: ...press OK 13 channel Mode Basic Basic functionality 26 channel Mode Extended Pixel mapping with pixels in groups of 2 28 channel Mode Normal 3 layer sets You can set the pixel length of the top Set 1...

Страница 15: ...3200K White 5600K CTB 7200K Color Chase 008 255 Override Set 1 Color Mixing Channels 5 5 000 255 Set 1 Red 6 6 000 255 Set 1 Green 7 7 000 255 Set 1 Blue 8 8 000 255 Set 1 White 9 000 255 Set 1 Inten...

Страница 16: ...17 000 255 Set 2 White 18 000 255 Set 2 Intensity 19 000 007 008 015 016 023 024 031 032 039 040 047 048 055 056 063 064 071 072 079 080 087 088 095 096 103 104 111 112 119 120 127 128 255 Set 3 Colo...

Страница 17: ...Pixel 1 Blue 10 000 255 Pixel 1 White 11 000 255 Pixel 2 Red 12 000 255 Pixel 2 Green 13 000 255 Pixel 2 Blue 14 000 255 Pixel 2 White 15 000 255 Pixel 3 Red 16 000 255 Pixel 3 Green 17 000 255 Pixel...

Страница 18: ...ction and wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a unit...

Страница 19: ...rmal Max Operating Temp 104 degrees F 40 degrees C ambient Control Protocol USITT DMX 512 DMX Channels 13 26 28 46 channel modes Input Output 3 5 pin DMX RJ45 input output connections Other Operating...

Страница 20: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Отзывы: