Blizzard Mister Stroboto Скачать руководство пользователя страница 7

Page 7

Mister Stroboto™ Manual - Rev. A    

 

(c) 2019 Blizzard Lighting, LLC

Fuse Replacement

Mister Stroboto™ utilizes a high-output switch-mode power supply 

with an internal fuse. Under normal operating conditions, it should not 

require replacement. Should the fuse require replacement, please con-

tact Blizzard Lighting for instructions, or to return your unit for service.

Connecting A Bunch of Mister Stroboto™ Fixtures

You will need a serial data link to run light shows using a DMX-512 

controller or to run shows on two or more fixtures set to sync in mas

-

ter/slave operating mode. The combined number of channels required 

by all the fixtures on a serial data link determines the number of fix

-

tures the data link can support.

Fixtures on a serial data link must be daisy chained in one single line. 

Also, connecting more than 32 fixtures on one serial data link without 

the use of a DMX optically-isolated splitter may result in deterioration 

of the digital DMX signal. The maximum recommended cable-run dis-

tance is 500 meters (1640 ft).  The maximum recommended number 

of fixtures on a serial data link is 32 fixtures.

Data/DMX Cabling

To link fixtures together you’ll need data cables.  You should use data-

grade cables that can carry a high quality signal and are less prone to 

electromagnetic interference.

For instance, Belden© 9841 meets the specifications for EIA RS-485 

applications. Standard microphone cables will “probably” be OK, but 

note that they cannot transmit DMX data as reliably over long distanc-

es.  In any event, the cable should have the following characteristics:

 

2-conductor twisted pair plus a shield

 

Maximum capacitance between conductors – 30 pF/ft.

 

Maximum capacitance between conductor & shield – 55 pF/ft.

 

Maximum resistance of 20 ohms / 1000 ft.

 

Nominal impedance 100 – 140 ohms

Before replacing a fuse, disconnect the power cord. 

ALWAYS replace with the same type and rating of fuse.

3. SETUP

Содержание Mister Stroboto

Страница 1: ...Blizzard Lighting LLC http www blizzardpro com Waukesha WI USA Copyright c 2019...

Страница 2: ...Mister Stroboto Pin up Picture 6 3 Setup 7 Fuse Replacement 7 Connecting A Bunch Of Mister Stroboto Fixtures 7 Data DMX Cables 7 Cable Connectors 8 3 Pin 5 Pin Huh 8 Fixture Linking Master Slave Mode...

Страница 3: ...ocal power supply See the label on the fixture or refer to the fixture s specifications chart for more information A fixture s listed current rating is its average current draw under normal conditions...

Страница 4: ...ation slots are blocked ALWAYS disconnect from the power source before servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER...

Страница 5: ...isplay with 4 button control Operating modes DMX512 Master Slave Auto DMX Quick Reference 2 4 12 29 45 Channel Modes 2CH 4CH 12CH 29CH 45CH What It Does 1 1 1 1 Dimmer 0 100 1 2 2 2 2 Strobe 3 3 3 Fla...

Страница 6: ...oboto Pin Up Picture Figure 2 The Rear Connections Figure 1 Mister Stroboto Pin Up Picture 4 Button Control Panel with 2 4 TFT Color Display 32 3 watt 3 in 1 RGB LEDs 8 100 watt 6500K CTO White LEDs C...

Страница 7: ...ata link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal The maximum recommended cable run dis tance is 500 meters 1640 ft The maximum recomm...

Страница 8: ...the chart below details a proper cable conversion Conductor 3 pin Male Input 5 Pin Female Output Ground Shield Pin 1 Pin 1 Data 1 Primary Data Link Pin 2 Pin 2 Data 1 Primary Data Link Pin 3 Pin 3 Da...

Страница 9: ...he fixtures that follow may also require a slave setting Check the Operating Adjustments section in this manual for com plete instructions for this type of setup and configuration Mounting Rigging Thi...

Страница 10: ...odic safety inspection of all installation material and the fixture If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury Caution...

Страница 11: ...able rigging point together When mounting this fixture to truss be sure to secure an appropriately rated clamp to the omega bracket using an M10 screw fitted through the center hole of the omega brack...

Страница 12: ...the current selection UP Scrolls through menu items and numbers in ascending order DOWN Scrolls through menu items and numbers in descending order The control panel display shows the menu items you se...

Страница 13: ...See pages 14 15 Strobe 000 255 Strobe Program 000 255 Program Speed 000 255 Background Dimmer 000 255 Background Strobe 000 255 Color Macro 000 255 Macro Auto 000 255 Macro Speed 000 255 Settings Dis...

Страница 14: ...LED Dimmer 1 0 100 5 5 000 255 White LED Dimmer 2 0 100 6 6 000 255 White LED Dimmer 3 0 100 7 7 000 255 White LED Dimmer 4 0 100 8 000 255 White LED Dimmer 5 0 100 9 000 255 White LED Dimmer 6 0 100...

Страница 15: ...9 Program 10 131 142 143 154 155 166 167 178 179 190 191 202 203 214 215 226 227 238 239 255 Program 11 Program 12 Program 13 Program 14 Program 15 Program 16 Program 17 Program 18 Program 19 Program...

Страница 16: ...3 pin mic cables although this does not conform to the defined standard DMX is connected using a daisy chain configuration where the source connects to the input of the first device the output of the...

Страница 17: ...d wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a unit in for s...

Страница 18: ...F 40 degrees C ambient Control Protocol USITT DMX 512 Art Net RDM DMX Channels 2 4 12 29 45 Input 5 pin XLR Male Output 5 pin XLR Female Other Operating Modes DMX512 Master Slave Auto Warranty 2 year...

Страница 19: ...Page 19 Mister Stroboto Manual Rev A c 2019 Blizzard Lighting LLC Dimensional Drawings 11 3 287 mm 3 9 287 mm 4 6 116 6 mm 8 9 225 8 mm 17 4 439 8 mm 19 481 5 mm 20 1 508 5 mm...

Страница 20: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Отзывы: