Blizzard Mister Stroboto Скачать руководство пользователя страница 16

Page 16

Mister Stroboto™ Manual - Rev. A    

 

(c) 2019 Blizzard Lighting, LLC

5. APPENDIX

A Quick Lesson On DMX

DMX (aka DMX-512) was created in 1986 by the United States Institute for Theatre 

Technology (USITT) as a standardized method for connecting lighting consoles to lighting 

dimmer modules. It was revised in 1990 and again in 2000 to allow more flexibility.  The 

Entertainment Services and Technology Association (ESTA) has since assumed control over 

the DMX512 standard.  It has also been approved and recognized for ANSI standard clas-

sification.  

DMX covers (and is an abbreviation for) Digital MultipleXed signals. It is the most common 

communications standard used by lighting and related stage equipment.  

DMX provides up to 512 control “channels” per data link. Each of these channels was origi-

nally intended to control lamp dimmer levels. You can think of it as 512 faders on a lighting 

console, connected to 512 light bulbs. Each slider’s position is sent over the data link as an 

8-bit number having a value between 0 and 255. The value 0 corresponds to the light bulb 

being completely off while 255 corresponds to the light bulb being fully on. 

DMX data is transmitted at 250,000 bits per second using the RS-485 transmission stan-

dard over two wires. As with microphone cables, a grounded cable shield is used to prevent 

interference with other signals.

There are five pins on a DMX connector: a wire for ground (cable shield), two wires for 

“Primary” communication which goes from a DMX source to a DMX receiver, and two wires 

for a “Secondary” communication which goes from a DMX receiver back to a DMX source. 

Generally, the “Secondary” channel is not used so data flows only from sources to receiv

-

ers.  Hence, most of us are most familiar with DMX-512 as being employer over typical 

3-pin “mic cables,” although this does not conform to the defined standard.

DMX is connected using a daisy-chain configuration where the source connects to the input 

of the first device, the output of the first device connects to the input of the next device, 

and so on. The standard allows for up to 32 devices on a single DMX link. 

Each receiving device typically has a means for setting the “starting channel number” that 

it will respond to. For example, if two 6-channel fixtures are used, the first fixture might 

be set to start at channel 1 so it would respond to DMX channels 1 through 6, and the next 

fixture would be set to start at channel 7 so it would respond to channels 7 through 12.

The greatest strength of the DMX communications protocol is that it is very simple and 

robust.  It involves transmitting a reset condition (indicating the start of a new “packet”), 

a start code, and up to 512 bytes of data. Data packets are transmitted continuously. As 

soon as one packet is finished, another can begin with no delay if desired (usually another 

follows within 1 ms). If nothing is changing (i.e. no lamp levels change) the same data will 

be sent out over and over again. This is a great feature of DMX -- if for some reason the 

data is not interpreted the first time around, it will be re-sent shortly.

Not all 512 channels need to be output per packet, and in fact, it is very uncommon to find 

all 512 used.  The fewer channels are used, the higher the “refresh” rate. It is possible to 

get DMX refreshes at around 1000 times per second if only 24 channels are being trans-

mitted. If all 512 channels are being transmitted, the refresh rate is around 44 times per 

second.

In summary, since its design and evolution in the 1980’s DMX has become the standard 

for lighting control.  It is flexible, robust, and scalable, and its ability to control everything 

from dimmer packs to moving lights to foggers to lasers makes it an indispensable tool for 

any lighting designer or lighting performer.

Содержание Mister Stroboto

Страница 1: ...Blizzard Lighting LLC http www blizzardpro com Waukesha WI USA Copyright c 2019...

Страница 2: ...Mister Stroboto Pin up Picture 6 3 Setup 7 Fuse Replacement 7 Connecting A Bunch Of Mister Stroboto Fixtures 7 Data DMX Cables 7 Cable Connectors 8 3 Pin 5 Pin Huh 8 Fixture Linking Master Slave Mode...

Страница 3: ...ocal power supply See the label on the fixture or refer to the fixture s specifications chart for more information A fixture s listed current rating is its average current draw under normal conditions...

Страница 4: ...ation slots are blocked ALWAYS disconnect from the power source before servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER...

Страница 5: ...isplay with 4 button control Operating modes DMX512 Master Slave Auto DMX Quick Reference 2 4 12 29 45 Channel Modes 2CH 4CH 12CH 29CH 45CH What It Does 1 1 1 1 Dimmer 0 100 1 2 2 2 2 Strobe 3 3 3 Fla...

Страница 6: ...oboto Pin Up Picture Figure 2 The Rear Connections Figure 1 Mister Stroboto Pin Up Picture 4 Button Control Panel with 2 4 TFT Color Display 32 3 watt 3 in 1 RGB LEDs 8 100 watt 6500K CTO White LEDs C...

Страница 7: ...ata link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal The maximum recommended cable run dis tance is 500 meters 1640 ft The maximum recomm...

Страница 8: ...the chart below details a proper cable conversion Conductor 3 pin Male Input 5 Pin Female Output Ground Shield Pin 1 Pin 1 Data 1 Primary Data Link Pin 2 Pin 2 Data 1 Primary Data Link Pin 3 Pin 3 Da...

Страница 9: ...he fixtures that follow may also require a slave setting Check the Operating Adjustments section in this manual for com plete instructions for this type of setup and configuration Mounting Rigging Thi...

Страница 10: ...odic safety inspection of all installation material and the fixture If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury Caution...

Страница 11: ...able rigging point together When mounting this fixture to truss be sure to secure an appropriately rated clamp to the omega bracket using an M10 screw fitted through the center hole of the omega brack...

Страница 12: ...the current selection UP Scrolls through menu items and numbers in ascending order DOWN Scrolls through menu items and numbers in descending order The control panel display shows the menu items you se...

Страница 13: ...See pages 14 15 Strobe 000 255 Strobe Program 000 255 Program Speed 000 255 Background Dimmer 000 255 Background Strobe 000 255 Color Macro 000 255 Macro Auto 000 255 Macro Speed 000 255 Settings Dis...

Страница 14: ...LED Dimmer 1 0 100 5 5 000 255 White LED Dimmer 2 0 100 6 6 000 255 White LED Dimmer 3 0 100 7 7 000 255 White LED Dimmer 4 0 100 8 000 255 White LED Dimmer 5 0 100 9 000 255 White LED Dimmer 6 0 100...

Страница 15: ...9 Program 10 131 142 143 154 155 166 167 178 179 190 191 202 203 214 215 226 227 238 239 255 Program 11 Program 12 Program 13 Program 14 Program 15 Program 16 Program 17 Program 18 Program 19 Program...

Страница 16: ...3 pin mic cables although this does not conform to the defined standard DMX is connected using a daisy chain configuration where the source connects to the input of the first device the output of the...

Страница 17: ...d wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a unit in for s...

Страница 18: ...F 40 degrees C ambient Control Protocol USITT DMX 512 Art Net RDM DMX Channels 2 4 12 29 45 Input 5 pin XLR Male Output 5 pin XLR Female Other Operating Modes DMX512 Master Slave Auto Warranty 2 year...

Страница 19: ...Page 19 Mister Stroboto Manual Rev A c 2019 Blizzard Lighting LLC Dimensional Drawings 11 3 287 mm 3 9 287 mm 4 6 116 6 mm 8 9 225 8 mm 17 4 439 8 mm 19 481 5 mm 20 1 508 5 mm...

Страница 20: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Отзывы: