background image

TO ENSURE OPTIMAL PERFORMANCE FROM YOUR ICEMAKER, THE 
FOLLOWING IS RECOMMENDED –  

 

 

Ensure that the minimum water temperature is not lower than 

+5°C

 or higher than 

+40°C

 

 

Minimum water pressure is not below 0.1MPa and maximum does 
not exceed 0.5MPa 

 

The electrical supply available corresponds to the voltage and 
ampacity of the machine specifications as indicated on the rating 
plate 

 

The electrical cut off switch with fuse protection must be a 2 pole 
type with minimum clearance of 3mm between open contacts 

 

The minimum ambient temperature should not be lower than 

+10°C

 or the maximum higher than 

+40°C

 

 

Ensure there is a minimum space around the cabinet vents of 
150mm to allow air circulation. 

 

Ensure there are no heat sources (kitchen stoves, cookers, radiators 
etc) near the machine and the environment isn’t too humid. 

 

INSTALLATION 

 

 

Check the machine is level, and connect the plug to the electrical 
cord in compliance with local regulations 

 

Replace any old/used water hoses with new ones and connect to the 
water supply 

 

Ensure the drain is connected and set up properly using a spiralled 
hose.  It should have a minimum fall of 3cm per metre 

 

Open water shut off valve 

 

Insert plug into mains socket and set the main switch to the ON 
position. 

 

 

Содержание ICY20

Страница 1: ...INTEGRAL ICE CUBERS MANUAL OF INSTRUCTIONS FOR USE AND INSTALLATION...

Страница 2: ...s we hope and expect it to bring you problem free and efficient usage in the future Please read this manual thoroughly and acquaint yourself with the correct installation and operation methods Adherin...

Страница 3: ...differ slightly from the machine supplied Any illustration schematic or document supplied with the machine remain the property of the manufacturer who retain copyright and distribution rights The manu...

Страница 4: ...supply control switch must be within arms reach of the installed machine Do NOT remove any service panel secured with screws The water shut off valve must also be within arms length of the installed...

Страница 5: ...m the unit Ensure the ice scoop is located inside the ice storage bin LOCATING Position the icemaker in it s final location and make sure everything need for installation is present such as Power supp...

Страница 6: ...mbient temperature should not be lower than 10 C or the maximum higher than 40 C Ensure there is a minimum space around the cabinet vents of 150mm to allow air circulation Ensure there are no heat sou...

Страница 7: ...specific hand disconnect switch or the main unit ON OFF switch DAILY PRECAUTIONS To prevent the build up of bacteria or other contaminants please observe the following advice Do not store anything in...

Страница 8: ...ANING OF THE WATER CIRCUIT Special attention must be observed to the importance of cleaning the water system To perform this cleaning contact an appropriately qualified person at least twice a year if...

Страница 9: ...connected to the mains Check blown fuses at the fusebox Ensure the plug is fully inserted into the power socket ICE MAKING CAPACITY REDUCED OR INEFFICIENT Is the water shut off valve open Is water an...

Страница 10: ...lusive to Pentland Wholesale Ltd For further information images or specifications please visit our website www pentlandwholesale co uk For spares or parts breakdowns please contact our spares departme...

Отзывы: