PENTLAND WHOLESALE LTD. www.pentlandwholesale.co.uk
+44 01254 614444
NOTICE!
●
When the thunderstorm is coming, the electricity supply must be cut
off soon.
It will avoid the equipment being damaged in cause of lightning
stroke.
●
Do not destroy the control panel and the surface of the machine with
hard or sharp things.
●
When the machine finishes using , user should close main switch.
●
The installation and maintenance of circuit must be done by
certificated special professionals.
If the supply cord is damaged, it must be replaced by the
manufacturer or its service agent or a similarly qualified person in
order to avoid a calamity.
Operation Instruction
Before using, check whether the power supply installation is regular to make sure the supplied voltage is
coordinated with the using one.
Put the plug in the socket and turn on the power.
Turn the temperature controller clockwise to the temperature needed. The yellow indicator is on that shows heating
wire begins to heat and the upper and lower griddle begins to raise temperature.
Temperature can be adjusted according to different food preferably within 180
℃
~250
℃.
About 8 minutes
is
needed for the temperature to be raised to 250
℃
from the power is on.
When the temperature reaches 250
℃,
lift the upper module plate to a suitable place by operation handle. Put some
edible vegetable oil on the lower module plate and constantly place the food on it. Close the plates and press the
handle lightly. Keep an eye on the food until it is suitably done.
When temperature reaches the setting degree, temperature controller can cut off power supply automatically. At the
same time, yellow indicator is off and green indicator is on. It shows that electricity heating tube stops working for
next turn.
At the lower front of the lower module is the oil tray. Substantial vegetable oil and the animal oil from the meat
grilled flow to the oil tray from the lower module plate.
Lift the upper module plate to take the sandwich and other food already done.
When the temperature is a bit lower, the temperature controller can get through power supply automatically. The
heating tubes restart to work to heat the module plates.
On completion of the work, temperature controller should be turned to the “off” place. Unplug the equipment and
cut off the power.
Notice: There is temperature limiter in the bottom box, the action temperature is 130
℃
, and reset temperature is
‹
40
℃.
When temperature is over the protective button works for protection. When use it again, please use it
after press the protective button.
Cleaning and Maintenance
Cut off the power supply before cleaning in case of accident.
Do not use wet towel with non-corrosive cleanser to clean the module plate, the surface of the equipment and power