7
HOW TO DISPLAY THE REGULATION SET POINTS
By pushing the SET key the following information are
displayed in sequence:
-
rSI
= Room set point
-
iSI
= Stop phase set point, referred to the insert probe
- Back to the room temperature.
HOW TO MODIFY THE ROOM SET POINT
While rSI or iSI are displayed hold pushed the SET key till
the rSi or iSi label start flashing and LED near the SET key
is turned on.
Use the arrow key to modify the value and the SET key to confirm it.
4. KEYBOARD WHEN THE HOLDING CYCLE IS RUNNING (H)
HOW TO DISPLAY THE HOLDING (REGULATION) SET POINT
While the holding cycle is running, (H icon lighted), push the SET
key and the holding set point is displayed on the UPPER display
while the
SETH
label on the bottom display.
HOW TO MODIFY THE ROOM SET POINT
While SETH is displayed hold pushed the SET key till the SETH label
starts flashing and LED near the SET key is turned on. Use the arrow
key to modify the value and the SET key to confirm it.
TO CONFIRM AND EXIT
: push again the SET key
5. OTHER KEYS
LIGHT
(4): push the LIGHT (4) key to switch the light on and off.
The status of the light is monitored by the yellow LED upper the
key.
AUX
(8): ): push the AUX (8) key to switch the auxiliary on and off.
The status of the auxiliary relay is monitored by the yellow LED
Upper the key.
PRINTER
/ H (7): push the PRINTER key when the keyboard is
connected to the controller, to enabled/ disable the printer.
PRINTER CONFIGURATION MENU
Push the PRINTER (7) key for few seconds to enter the
printer configuration menu. The
itP
, label is displayed, use
the ARROW keys to browse the parameters
To modify:
push the
SET
key and then the ARROW keys.
To confirm
: push the
SET
key
To exit the Printer menu
: Push together SET + UP keys
or wait 5 sec