Blizzard Lighting ToughStick 5 Скачать руководство пользователя страница 3

Page 3

ToughStick™ 5 User Manual Rev. A   

 

© 2013 Blizzard Lighting, LLC

1. GettiNG started

What’s In The Box?

 

 

• 1 x ToughSTICK™ 5

 

• 1 x Waterproof Power Cable

 

• 2 x Waterproof DMX Cables (1 male, 1 female)

 

• 2 x Mounting Brackets

 

• This Lovely User Manual

Optional Accessories 

(sold separately)

The following accessories are available for this fixture. But the lone wolves that they are, they 

must be purchased separately. Contact your authorized Blizzard Lighting dealer for pricing!

•  DMX-EXT: 3-Meter IP-Rated DMX Extension Cable

•  PWR-EXT: 3-Meter IP-Rated Power Extension Cable

Getting It Out Of The Box

 

Congratulations on purchasing one of the most rocking box-shaped PAR fixtures anywhere!  Now 

that you’ve got your ToughStick™ 5 fixture (or hopefully, 

ToughStick 5’s!

), you should carefully 

unpack the box and check the contents to ensure that all parts are present and in good condi-

tion. If anything looks as if it has been damaged in transit, notify the shipper immediately and 

keep the packing material for inspection.  Again, please save the carton and all packing materi-

als. If a fixture must be returned to the factory, it is important that the fixture be returned in 

the original factory box and packing.

Powering Up! 

All fixtures must be powered directly off a switched circuit and 

cannot be run off a rheostat 

(variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used 

solely for a 0% to 100% switch

.  

AC Voltage Switch -

 Not all fixtures have a voltage select switch, so please verify that the fixture 

you receive is suitable for your local power supply.  See the label on the fixture or refer to the 

fixture’s specifications chart for more information.  A fixture’s listed current rating is its average 

current draw under normal conditions. Check the fixture or device carefully to make sure that if 

a voltage selection switch exists that it is set to the correct line voltage you will use.

 

Warning! 

Verify that the voltage select switch on your unit matches the line voltage 

applied. Damage to your fixture may result if the line voltage applied does not match 

the voltage indicated on the voltage selector switch. All fixtures must be connected to 

circuits with a suitable Ground (Earthing).

Getting A Hold Of Us

If something is wrong, just give us a call or send an email.  We’ll be happy to help, 

honest. 

 

Blizzard Lighting

N16 W23390 Stoneridge Dr. Suite E

Waukesha, WI 53188 USA

www.blizzardlighting.com

414-395-8365

Email: [email protected]

Disclaimer:

 The information and specifications contained in this document are subject to 

change without notice. Blizzard Lighting™ assumes no responsibility or liability for any errors or 

omissions that may appear in this user manual. Blizzard Lighting™ reserves the right to update 

the existing document or to create a new document to correct any errors or omissions at any 

time. You can download the latest version of this document from www.blizzardlighting.com.

Author:

Date:

Last Edited:

Date:

J. Thomas

7/31/2013

J. Thomas

7/31/2013

Содержание ToughStick 5

Страница 1: ...Blizzard Lighting LLC www blizzardlighting com Waukesha WI USA Copyright c 2013 TOUGHSTICK TM suitable for outdoor use ...

Страница 2: ... Connecting A Bunch Of ToughStick 5 Fixtures 7 Data DMX Cables 7 Cable Connectors 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting up DMX Control 8 Fixture Linking Master Slave Mode 9 Mounting Rigging 9 4 Operating Adjustments 10 Navigating The Control Panel 10 Control Panel Menu Structure 11 DMX Mode 12 Master Slave Mode 12 Sound Active Mode 12 Standalone Program Mode 12 Manual Color Adjustm...

Страница 3: ...0 to 100 switch AC Voltage Switch Not all fixtures have a voltage select switch so please verify that the fixture you receive is suitable for your local power supply See the label on the fixture or refer to the fixture s specifications chart for more information A fixture s listed current rating is its average current draw under normal conditions Check the fixture or device carefully to make sure ...

Страница 4: ... servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles DO NOT operate at ambient temperatures higher than 104 F 40 C In the event of a serious operating problem stop using the unit immediately NEVER try to repair the unit by yourself Repairs carried out by unskilled peo...

Страница 5: ...tion cooling IP Rated AC power cord with cable cap IP Rated DMX in out cables Dual mounting brackets for positioning flexibility DMX Quick Reference 9 10 Channel Mode Channel 9 Channel 10 Channel 1 Dimmer Dimmer 2 Red Intensity Red Intensity 3 Green Intensity Green Intensity 4 Blue Intensity Blue Intensity 5 Amber Intensity Amber UV Intensity 6 White Intensity White Intensity 7 Strobe Strobe 8 Bui...

Страница 6: ...att 5 in 1 RGBAW LED s Black Powder Coated Aluminum Housing LED Control Panel Figure 2 The Rear Connections AC Power In 3 Pin DMX512 In AC Power Out 3 Pin DMX512 Out Extended waterproof AC power and 3 pin DMX connections Mounting Brackets with Adjustment Locking Knobs IP65 Rated Weatherproof Power DMX Connections ...

Страница 7: ...xtures on a serial data link must be daisy chained in one single line Also connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal The maximum recommended cable run distance is 500 meters 1640 ft The maximum recommended number of fixtures on a serial data link is 32 fixtures Data DMX Cabling...

Страница 8: ... like to build your own the chart below details a proper cable conversion Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 DMX Data Pin 2 Pin 2 DMX Data Pin 3 Pin 3 Not Used No Connection No Connection Not Used No Connection No Connection Take It To The Next Level Setting Up DMX Control Step 1 Connect the male connector of the DMX cable to the female connector output on the...

Страница 9: ...the Operating Adjustments section in this manual for com plete instructions for this type of setup and configuration Mounting Rigging This fixture may be mounted in any SAFE position provided there is enough room for ventilation It is important never to obstruct the fan or vents pathway Mount the fixture using a suitable C or O type clamp The clamp should be rated to hold at least 10x the fixture ...

Страница 10: ...crolls through menu items and numbers in descending order ENTER Is used to select and confirm store the current selection The Control Panel LED Display shows the menu items you select from the menu map on page 11 When a menu function is selected the display will show immediately the first available option for the selected menu function To select a menu item press ENTER Press the MENU button repeat...

Страница 11: ...X mode SP SP00 SP15 Speed adjustments 0 15 Pr Pr00 Pr35 Built in programs 0 35 ASC AC00 AC15 Auto mode 0 15 FAdE FA00 FA15 Fade settings 0 15 FLAS FL00 FL15 Flash strobe speed 0 15 rL r 000 r 255 Red dimmer 0 100 GL G 000 G 255 Green dimmer 0 100 bL b 000 b 255 Blue dimmer 0 100 AL A 000 A 255 Amber or UV dimmer 0 100 UL U 000 U 255 White dimmer 0 100 SouA So uA Sound active mode LED on oFF Displa...

Страница 12: ...button to confirm 3 To use the fixture in automatic mode select ASC and press the ENTER button Then use the UP DOWN to choose from AS00 AS15 then press the ENTER button to confirm 4 Adjust the speed of the chase as above using SP15 slowest to SP00 fastest then press the ENTER button to confirm 5 To set the fixture as a slave unit select SLAU and hit ENTER The unit will display a flashing SL AU to ...

Страница 13: ...000 005 006 055 056 105 106 155 156 205 206 255 32 Bit Dimmer As set in the control menu display Mode 0 8 bit 256 dimming steps Mode 1 32 bit 0 25 intensity range Mode 2 32 bit 0 50 intensity range Mode 3 32 bit 0 75 intensity range Mode 4 32 bit full intensity dimming DMX Values In Depth 9 Channel Mode Channel Value What It Does 1 000 255 Dimmer 0 100 2 000 255 Red Intensity 0 100 3 000 255 Green...

Страница 14: ...d that unit s ventilation is not obstructed Slow Movement Verify that 220V 110V switch is in the correct position if appli cable Also check that speed channels are set appropriately No Response to Audio Verify that the fixture is in Sound Active mode Adjust Audio Sensitivity If Applicable Fixture Not Responding Responding Erraticly Make sure all connectors are seated properly and securely Use Only...

Страница 15: ... 3 pin mic cables although this does not conform to the defined standard DMX is connected using a daisy chain configuration where the source connects to the input of the first device the output of the first device connects to the input of the next device and so on The standard allows for up to 32 devices on a single DMX link Each receiving device typically has a means for setting the starting chan...

Страница 16: ...satisfaction and wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a unit in for service But like any complex piece of equipment designed and built by humans once in a while something doesn t go as planned If you find yourself with a fixture that isn t behaving like ...

Страница 17: ...ight Source LED 9x 15W 5 in 1 LEDs 100 000 hours Optical Beam Angle 25 degree optics standard Thermal Max Operating Temp 104 degrees F 40 degrees C ambient Control Protocol USITT DMX 512 DMX Channels 4 5 9 10 Input 3 pin XLR Male Output 3 pin XLR Female Other Operating Modes Standalone Master Slave Sound Active Color Preset Other Information Right now I m having amnesia and deja vu at the same tim...

Страница 18: ...Page 18 ToughStick 5 User Manual Rev A 2013 Blizzard Lighting LLC This page intentionally left blank ...

Страница 19: ...Page 19 ToughStick 5 User Manual Rev A 2013 Blizzard Lighting LLC This page intentionally left blank ...

Страница 20: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting ...

Отзывы: