Blizzard Lighting Stiletto Z7 Скачать руководство пользователя страница 7

Page 7

Stiletto™ Z7 Moving Head - Rev. A   

 

(c) 2015 Blizzard Lighting, LLC

3. SETUP

Fuse Replacement

With a philips head screwdriver, unscrew the fuse holder out of its 

housing. Remove the damaged fuse from its holder and replace with 

exact same type which is a 5A, 250V micro-fuse. Reattach the fuse 

holder, and then reconnect power.

Connecting A Bunch of Stiletto Z7 Fixtures™

You will need a serial data link to run light shows using a DMX-512 

controller or to run shows on two or more fixtures set to sync in mas

-

ter/slave operating mode. The combined number of channels required 

by all the fixtures on a serial data link determines the number of fix

-

tures the data link can support.

Fixtures on a serial data link must be daisy chained in one single line. 

Also, connecting more than 32 fixtures on one serial data link without 

the use of a DMX optically-isolated splitter may result in deterioration 

of the digital DMX signal. The maximum recommended cable-run dis-

tance is 500 meters (1640 ft).  The maximum recommended number 

of fixtures on a serial data link is 32 fixtures.

Data/DMX Cabling

To link fixtures together you’ll need data cables.  You should use data-

grade cables that can carry a high quality signal and are less prone to 

electromagnetic interference.

For instance, Belden© 9841 meets the specifications for EIA RS-485 

applications. Standard microphone cables will “probably” be OK, but 

note that they cannot transmit DMX data as reliably over long distanc-

es.  In any event, the cable should have the following characteristics:

 

2-conductor twisted pair plus a shield

 

Maximum capacitance between conductors – 30 pF/ft.

 

Maximum capacitance between conductor & shield – 55 pF/ft.

 

Maximum resistance of 20 ohms / 1000 ft.

 

Nominal impedance 100 – 140 ohms

Содержание Stiletto Z7

Страница 1: ...Blizzard Lighting LLC www blizzardlighting com Waukesha WI USA Copyright c 2015 ...

Страница 2: ...Cables 7 Cable Connectors 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting up DMX Control 8 Fixture Linking Master Slave Mode 9 Mounting Rigging 9 Mounting Points 10 Clamp Mounting 11 Securing the fixture 11 4 Operating Adjustments 12 The Control Panel 12 Control Panel Menu Structure 13 Advanced Settings 13 View Fixture Info Hours Version 13 Display On Off 13 Manual Adjustments 13 DMX Auto So...

Страница 3: ...refer to the fixture s specifications chart for more information A fixture s listed current rating is its average current draw under normal conditions Check the fixture or device carefully to make sure that if a voltage selection switch exists that it is set to the correct line voltage you will use Warning Verify that the voltage select switch on your unit matches the line voltage applied Damage t...

Страница 4: ... moisture Make sure there are no flammable materials close to the unit while operating The unit must be installed in a location with adequate ventilation at least 20in 50cm from adjacent surfaces Be sure that no ventilation slots are blocked ALWAYS disconnect from the power source before servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a s...

Страница 5: ...tical system 3 pin male female input and outputs AC power input connector CONTROL USITT DMX 512 15 12 channel DMX modes 3 pin DMX input and output Easy to use 4 button LCD control panel DMX Quick Reference 15 12 Channel Modes Channel Standard Short Mode 1 Pan Pan 2 Fine Pan Tilt 3 Tilt Zoom 4 Fine Tilt Dimmer 5 Pan Tilt Speed Strobe 6 Zoom Red Intensity 7 Dimmer Green Intensity 8 Strobe Blue Inten...

Страница 6: ...lizzard Lighting LLC Figure 1 The Stiletto Z7 Pin Up Picture Menu Buttons LCD Display Head Arm 7 15 watt OSRAM RGBW LEDs Figure 2 The Rear Connections DMX Output Power Switch Power Input fixed cable DMX Input Fuse Holder 5A 250V Fan Vent Air Vent ...

Страница 7: ...re than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal The maximum recommended cable run dis tance is 500 meters 1640 ft The maximum recommended number of fixtures on a serial data link is 32 fixtures Data DMX Cabling To link fixtures together you ll need data cables You should use data grade cables tha...

Страница 8: ... like to build your own the chart below details a proper cable conversion Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 DMX Data Pin 2 Pin 2 DMX Data Pin 3 Pin 3 Not Used No Connection No Connection Not Used No Connection No Connection Take It To The Next Level Setting Up DMX Control Step 1 Connect the male connector of the DMX cable to the female connector output on the...

Страница 9: ...the Operating Adjustments section in this manual for com plete instructions for this type of setup and configuration Mounting Rigging This fixture may be mounted in any SAFE position provided there is enough room for ventilation It is important never to obstruct the fan or vents pathway Mount the fixture using a suitable C or O type clamp The clamp should be rated to hold at least 10x the fixture ...

Страница 10: ...y inspection of all installation material and the fixture If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury Caution Please be aware you should have a qualified electrician performing all of your electrical connection needs Better safe than sorry Be sure to complete all rigging and installation procedures before connecting th...

Страница 11: ...to the bottom side of the base They should be attached with M10 mm thread bolts max length 11mm This is necessary to cope with the torque which accrues in this mounting position Never use a centered single clamp to fasten the fixture in the sideways position Safe installation can not be assured in this way and can damage the fixture base Securing the Fixture Regardless of the mounting method of th...

Страница 12: ... selection UP Scrolls through menu items and numbers in ascending order DOWN Scrolls through menu items and numbers in descending order The control panel LCD display shows the menu items you select from the menu map on page 13 When a menu function is selected the display will show immediately the first available option for the selected menu function To select a menu item press ENTER Use the UP and...

Страница 13: ...ctive manual adjustment for 000 255 White Corrective manual adjustment for 000 255 Option P T Swap P T Swap OFF Swaps Pan Tilt for programming purposes P T Swap ON Swaps Pan Tilt for programming purposes Lost DMX Lost DMX Clear Sets fixture to clear last DMX program if DMX con nection is lost Lost DMX Hold Sets fixture to hold last DMX program if DMX con nection is lost Display DelayOff LCD displa...

Страница 14: ...gs Reset Yes Enter Select to Reset fixture settings DMX Values In Depth 15 12 Channel Modes Ch Value Standard 15ch Ch Value Short Mode 12ch 1 000 255 Pan 1 000 255 Pan 2 000 255 Fine Pan 2 000 255 Tilt 3 000 255 Tilt 3 000 255 Zoom 4 000 255 Fine Tilt 4 000 255 Dimmer 5 000 255 Pan Tilt Speed 5 000 255 Strobe 6 000 255 Zoom 6 000 255 Red Intensity 7 000 255 Dimmer 7 000 255 Green Intensity 8 000 2...

Страница 15: ... Power Check fuse AC cord and circuit for malfunction Blown Fuse Check AC cord and circuit for damage verify that moving parts are not restricted and that unit s ventilation is not obstructed Slow Movement Verify that 220V 110V switch is in the correct position if applicable Also check that speed channels are set appro priately No Response to Audio Verify that the fixture is in Sound Active mode A...

Страница 16: ... 3 pin mic cables although this does not conform to the defined standard DMX is connected using a daisy chain configuration where the source connects to the input of the first device the output of the first device connects to the input of the next device and so on The standard allows for up to 32 devices on a single DMX link Each receiving device typically has a means for setting the starting chan...

Страница 17: ...wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a unit in for service But like any complex piece of equipment designed and built by humans once in a while something doesn t go as planned If you find yourself with a fixture that isn t behaving like a good little fix...

Страница 18: ...uminous Intensity Narrow Beam 7 Lux m ALL Red Green Blue White 1m 42 700 9 600 10 900 12 000 13 900 2m 12 800 2 700 3 400 3 900 4 000 Wide Beam 50 Lux m ALL Red Green Blue White 1m 3 734 871 1 000 1 236 1 400 2m 906 204 239 316 329 Movement Range Pan 540 degrees Tilt 270 degrees Thermal Max Operating Temp 104 degrees F 40 degrees C ambient Control Protocol USITT DMX 512 DMX Channels 15 12 channels...

Страница 19: ...A c 2015 Blizzard Lighting LLC Dimensional Drawings 8 9 inches 226 3mm ø5 9 inches 148 5mm 9 inches 228 4mm 7 4 inches 187mm 5 8 inches 146 8mm 0 4 in 8 5mm 3 9 in 97 7mm ø7 5 inches 190mm 3 x M10 Max Length 11mm 3 5 in 89mm 1 8 in 45 5mm ...

Страница 20: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting ...

Отзывы: