The Puck Q6: Unplugged Manual Rev. A 

 

Copyright (c) 2012 Blizzard Lighting, LLC

5. APPENDIX 

A Quick Lesson On DMX

DMX (aka DMX-512) was created in 1986 by the United States Institute for Theatre 

Technology (USITT) as a standardized method for connecting lighting consoles to lighting 

dimmer modules. It was revised in 1990 and again in 2000 to allow more flexibility.  The 

Entertainment Services and Technology Association (ESTA) has since assumed control over 

the DMX512 standard.  It has also been approved and recognized for ANSI standard clas-

sification.  

DMX covers (and is an abbreviation for) Digital MultipleXed signals. It is the most common 

communications standard used by lighting and related stage equipment.  

DMX provides up to 512 control “channels” per data link. Each of these channels was origi-

nally intended to control lamp dimmer levels. You can think of it as 512 faders on a lighting 

console, connected to 512 light bulbs. Each slider’s position is sent over the data link as an 

8-bit number having a value between 0 and 255. The value 0 corresponds to the light bulb 

being completely off while 255 corresponds to the light bulb being fully on. 

DMX data is transmitted at 250,000 bits per second using the RS-485 transmission stan-

dard over two wires. As with microphone cables, a grounded cable shield is used to prevent 

interference with other signals.

There are five pins on a DMX connector: a wire for ground (cable shield), two wires for 

“Primary” communication which goes from a DMX source to a DMX receiver, and two wires 

for a “Secondary” communication which goes from a DMX receiver back to a DMX source. 

Generally, the “Secondary” channel is not used so data flows only from sources to receiv

-

ers.  Hence, most of us are most familiar with DMX-512 as being employer over typical 

3-pin “mic cables,” although this does not conform to the defined standard.

DMX is connected using a daisy-chain configuration where the source connects to the input 

of the first device, the output of the first device connects to the input of the next device, 

and so on. The standard allows for up to 32 devices on a single DMX link. 

Each receiving device typically has a means for setting the “starting channel number” that 

it will respond to. For example, if two 6-channel fixtures are used, the first fixture might 

be set to start at channel 1 so it would respond to DMX channels 1 through 6, and the next 

fixture would be set to start at channel 7 so it would respond to channels 7 through 12.

The greatest strength of the DMX communications protocol is that it is very simple and 

robust.  It involves transmitting a reset condition (indicating the start of a new “packet”), 

a start code, and up to 512 bytes of data. Data packets are transmitted continuously. As 

soon as one packet is finished, another can begin with no delay if desired (usually another 

follows within 1 ms). If nothing is changing (i.e. no lamp levels change) the same data will 

be sent out over and over again. This is a great feature of DMX -- if for some reason the 

data is not interpreted the first time around, it will be re-sent shortly.

Not all 512 channels need to be output per packet, and in fact, it is very uncommon to find 

all 512 used.  The fewer channels are used, the higher the “refresh” rate. It is possible to 

get DMX refreshes at around 1000 times per second if only 24 channels are being trans-

mitted. If all 512 channels are being transmitted, the refresh rate is around 44 times per 

second.

In summary, since its design and evolution in the 1980’s DMX has become the standard 

for lighting control.  It is flexible, robust, and scalable, and its ability to control everything 

from dimmer packs to moving lights to foggers to lasers makes it an indispensible tool for 

any lighting designer or lighting performer.

Содержание Puck Q6 Unplugged

Страница 1: ...Blizzard Lighting LLC www blizzardlighting com Wisconsin USA Copyright c 2012...

Страница 2: ...ick Reference 4 and 7 Channel Modes 6 The Puck Q6 Unplugged Pin up Picture 7 3 Setup 8 Fuse Replacement 8 Connecting A Bunch Of Puck Q6 Unplugged LED PAR Cans 8 Data DMX Cables 8 Using the Battery Sys...

Страница 3: ...tures above 25 C will shorten the life of the bat tery pack 5 DO NOT BURN OR INCINERATE BATTERY PACKS Battery packs may explode causing personal injury fire and or damage Fumes resulting from burning...

Страница 4: ...iginal factory box and packing Powering Up All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or dim...

Страница 5: ...before servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles DO NOT o...

Страница 6: ...DMX modes ADDITIONAL FEATURES Lightweight and Compact It kept its New Years resolution 4 Button LED control panel for easy programming Light source 6x 10 Watt LEDs Quad Color Dual bracket for flexibi...

Страница 7: ...c 2012 Blizzard Lighting LLC Figure 1 The Puck Q6 Unplugged Pin Up Picture Super Fly Quad Color LEDs Flat as a pancake Dual Mounting Yokes Figure 2 The Rear Connections AC Power In Out DMX In DMX Out...

Страница 8: ...ting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal The maximum recommended cable run distance...

Страница 9: ...ttery life Depending on program battery life may range from 3 to 20 hours Runtime luminous intensity testing data for Amber Q6A TBA Puck Q6W Unplugged Runtime Luminous Intensity Testing Approx maximum...

Страница 10: ...thout a controller 1 Use standard DMX cables to daisy chain your units together via the DMX con nector on the rear of the units 2 Choose a unit to function as the Master Select MAST The master unit mu...

Страница 11: ...t value 255 after using this mode 1 Select NAnu from the control panel then hit ENTER 2 Choose rEd GrEE bLuE or UhIT then hit ENTER to confirm 3 Using the UP DOWN keys select the color you wish to dis...

Страница 12: ...CIRCUMSTANCES IS BLIZZARD LIGHTING RESPONSIBLE FOR ANY DAMAGE FROM SUCH OPERATION Fixtures bearing the above logo MUST only use cable and connec tors which separate chassis case ground from cable shie...

Страница 13: ...t s proceed 1 Plug the wiCICLE Receiver into the DMX IN connector of the fixture and verify it is receiving power the STATUS LED should illuminate 2 Connect the AC DC adaptor to the the wiCICLE Transm...

Страница 14: ...der correct mode IE sound active auto DMX Etc if applicable Contact service for more information Chase Speed Too Fast Slow Check to ensure proper setup of speed adjustment No Power Check fuse AC cord...

Страница 15: ...typical 3 pin mic cables although this does not conform to the defined standard DMX is connected using a daisy chain configuration where the source connects to the input of the first device the output...

Страница 16: ...li ent s satistfaction and wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back o...

Страница 17: ...cal Beam Angle 25 degrees 29 degree field Luminous Intensity 7 630 Lux 1m Full White Red 2 000 Lux 1m Green 1 650 Lux 1m Blue 2 500 Lux 1m Thermal Max Operating Temp 104 degrees F 40 degrees C ambient...

Страница 18: ...Page 18 The Puck Q6 Unplugged Manual Rev A Copyright c 2012 Blizzard Lighting LLC This page has been intentionally left blank...

Страница 19: ...Page 19 The Puck Q6 Unplugged Manual Rev A Copyright c 2012 Blizzard Lighting LLC This page has been intentionally left blank...

Страница 20: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Отзывы: