Blizzard Lighting KRYO.MIX CMY Скачать руководство пользователя страница 18

Page 18

Kryo.Mix™ CMY User Manual - Rev. B  

 

 

(c) 2017 Blizzard Lighting, LLC

5. APPENDIX

A Quick Lesson On DMX

DMX (aka DMX-512) was created in 1986 by the United States Institute for Theatre 

Technology (USITT) as a standardized method for connecting lighting consoles to lighting 

dimmer modules. It was revised in 1990 and again in 2000 to allow more flexibility.  The 

Entertainment Services and Technology Association (ESTA) has since assumed control over 

the DMX512 standard.  It has also been approved and recognized for ANSI standard clas-

sification.  

DMX covers (and is an abbreviation for) Digital MultipleXed signals. It is the most common 

communications standard used by lighting and related stage equipment.  

DMX provides up to 512 control “channels” per data link. Each of these channels was origi-

nally intended to control lamp dimmer levels. You can think of it as 512 faders on a lighting 

console, connected to 512 light bulbs. Each slider’s position is sent over the data link as an 

8-bit number having a value between 0 and 255. The value 0 corresponds to the light bulb 

being completely off while 255 corresponds to the light bulb being fully on. 

DMX data is transmitted at 250,000 bits per second using the RS-485 transmission stan-

dard over two wires. As with microphone cables, a grounded cable shield is used to prevent 

interference with other signals.

There are five pins on a DMX connector: a wire for ground (cable shield), two wires for 

“Primary” communication which goes from a DMX source to a DMX receiver, and two wires 

for a “Secondary” communication which goes from a DMX receiver back to a DMX source. 

Generally, the “Secondary” channel is not used so data flows only from sources to receiv

-

ers.  Hence, most of us are most familiar with DMX-512 as being employer over typical 

3-pin “mic cables,” although this does not conform to the defined standard.

DMX is connected using a daisy-chain configuration where the source connects to the input 

of the first device, the output of the first device connects to the input of the next device, 

and so on. The standard allows for up to 32 devices on a single DMX link. 

Each receiving device typically has a means for setting the “starting channel number” that 

it will respond to. For example, if two 6-channel fixtures are used, the first fixture might 

be set to start at channel 1 so it would respond to DMX channels 1 through 6, and the next 

fixture would be set to start at channel 7 so it would respond to channels 7 through 12.

The greatest strength of the DMX communications protocol is that it is very simple and 

robust.  It involves transmitting a reset condition (indicating the start of a new “packet”), 

a start code, and up to 512 bytes of data. Data packets are transmitted continuously. As 

soon as one packet is finished, another can begin with no delay if desired (usually another 

follows within 1 ms). If nothing is changing (i.e. no lamp levels change) the same data will 

be sent out over and over again. This is a great feature of DMX -- if for some reason the 

data is not interpreted the first time around, it will be re-sent shortly.

Not all 512 channels need to be output per packet, and in fact, it is very uncommon to find 

all 512 used.  The fewer channels are used, the higher the “refresh” rate. It is possible to 

get DMX refreshes at around 1000 times per second if only 24 channels are being trans-

mitted. If all 512 channels are being transmitted, the refresh rate is around 44 times per 

second.

In summary, since its design and evolution in the 1980’s DMX has become the standard 

for lighting control.  It is flexible, robust, and scalable, and its ability to control everything 

from dimmer packs to moving lights to foggers to lasers makes it an indispensable tool for 

any lighting designer or lighting performer.

Содержание KRYO.MIX CMY

Страница 1: ...Blizzard Lighting LLC www blizzardlighting com Waukesha WI USA Copyright c 2017 ...

Страница 2: ...Pin up Picture 6 3 Setup 7 Fuse Replacement 7 Connecting A Bunch Of Kryo Mix CMY Fixtures 7 Data DMX Cables 7 Cable Connectors 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting up DMX Control 8 Installation 9 Mounting Points 10 Clamp Mounting 11 Securing the Fixture 11 4 Operating Adjustments 12 The Control Panel 12 Control Panel Menu Structure 13 DMX Values In Depth 15 Gobo Replacement 17 Tro...

Страница 3: ...ower supply See the label on the fixture or refer to the fixture s specifications chart for more information A fixture s listed current rating is its average current draw under normal conditions Check the fixture or device carefully to make sure that if a voltage selection switch exists that it is set to the correct line voltage you will use Warning Verify that the voltage select switch on your un...

Страница 4: ...e servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its head Use its carrying handles DO NOT operate at ambient temperatures higher than 104 F 40 C In the event of a serious operating problem stop using the unit immediately NEVER try to repair the unit by yourself Repairs carried out by unskilled pe...

Страница 5: ...4 Fine Tilt 16 bit 4 Fine Tilt 16 bit 5 Cyan 0 100 5 Pan Tilt Speed 5 Pan Tilt Speed 6 Magenta 0 100 6 Reset Power Functions 6 Reset Power Functions 7 Yellow 0 100 7 Cyan 0 100 7 Cyan 0 100 8 Color Wheel 1 8 Magenta 0 100 8 Magenta 0 100 9 Color Wheel 2 9 Yellow 0 100 9 Yellow 0 100 10 Color Wheel 3 10 Color Wheel 1 10 Color Wheel 1 11 Gobo Rotation Speed 11 Color Wheel 2 11 Color Wheel 2 12 Gobo ...

Страница 6: ...ard Lighting LLC Figure 1 Kryo Mix CMY Pin Up Picture Carry Handle Figure 2 The Rear Connections Power Input 5 Pin DMX Out Power Switch Fuse Holder 3 Pin DMX Out 5 Pin DMX In 3 Pin DMX In Head Arms LCD Display YODN R17 350W Light Source Control Buttons ...

Страница 7: ... one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal The maximum recommended cable run dis tance is 500 meters 1640 ft The maximum recommended number of fixtures on a serial data link is 32 fixtures Data DMX Cabling To link fixtures together you ll need data cables You should use data grade cables that can carry a high qua...

Страница 8: ...r fixture s Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 Data 1 Primary Data Link Pin 2 Pin 2 Data 1 Primary Data Link Pin 3 Pin 3 Data 2 Optional Secondary Data Link Pin 4 Pin 4 Data 2 Optional Secondary Data Link Pin 5 Pin 5 Take It To The Next Level Setting Up DMX Control Step 1 Connect the male connector of the DMX cable to the female connector output on the control...

Страница 9: ...ck the Operating Adjustments section in this manual for com plete instructions for this type of setup and configuration Mounting Rigging This fixture may be mounted in any SAFE position provided there is enough room for ventilation It is important never to obstruct the fan or vents pathway Mount the fixture using a suitable C or O type clamp The clamp should be rated to hold at least 10x the fixtu...

Страница 10: ...y inspection of all installation material and the fixture If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury Caution Please be aware you should have a qualified electrician performing all of your electrical connection needs Better safe than sorry Be sure to complete all rigging and installation procedures before connecting th...

Страница 11: ...re an appropriately rated clamp to the omega bracket using an M10 screw fitted through the center hole of the omega bracket Securing the Fixture Regardless of the rigging option you choose for your fixtures always be sure to secure your fixture with a safety cable Be sure to only use the designated rigging point found on the underside of the base assembly for the safety cable Never secure a safety...

Страница 12: ... descending order OK Is used to save any changes made to a menu setting MENU To return to the previous option or menu without changing the value Access control panel functions using the five panel buttons located directly to the right of the LCD display The control panel LCD display shows the menu items you select from the menu map on page 13 When a menu function is selected the display will show ...

Страница 13: ...menu There is a 30 second delay when striking the lamp to ensure cooling prior to restrike Strike Douse Signal Lost Default DMX Fail setting Hold Clr DMX Reset Enable Disable fixture reset ability in DMX control Yes No Fixture Reset Manually reset the fixture Cncl RST Pan Reverse Yes No Tilt Reverse Yes No XY Speed Pan and tilt speed Fast Normal Slow P T Correction Pan and tilt correction Yes No F...

Страница 14: ... CT Wheel 000 255 Gobo 1 Stat 000 255 Gobo 2 Rot 000 255 Gobo 2 Rot 000 255 Gobo R Fine 000 255 Prism 000 255 Prism Rot 000 255 Frost In Out 000 255 Zoom 000 255 Zoom Fine 000 255 Focus 000 255 Dimmer 000 255 Shutter 000 255 Display Flip Disp Nor Inv Language Chinese English Brightness 10 100 Backlight 90S Off Menu Rtn 90S Off Diagnostics Check Code 000 255 Clean Time Ilum Clean Count Ilum Clean L...

Страница 15: ...or 1 Color 2 Color 3 Color 4 Color 5 10 12 12 000 004 005 054 055 104 105 154 155 204 205 254 Color Wheel 3 White Color 1 Color 2 Color 3 Color 4 Color 5 11 13 13 000 255 Gobo Rotation fast slow 12 14 14 000 004 005 009 010 014 015 019 020 024 025 029 030 034 035 039 040 044 045 049 050 054 055 059 060 064 065 069 070 089 090 129 130 134 135 170 171 175 176 180 181 185 186 190 191 195 196 200 201 ...

Страница 16: ...16 16 000 001 127 128 189 190 194 195 255 Gobo Indexing Rotation Stop no rotation Linear rotating rotation Clockwise Rotation fast slow Stop no rotation Counter Clockwise Rotation slow fast 17 000 255 Gobo Indexing Rotation fine 15 17 18 000 004 005 063 064 127 128 191 192 255 Prism Open 12 Facet Prism Indexing Prism Rotation 36 Facet Prism Indexing Prism Rotation 16 18 19 000 255 000 001 127 128 ...

Страница 17: ...ped or moving slower than normal the unit may have shut itself off due to high heat This is to protect the fixture from overheating Clear the fan of obstructions or return the unit for service Beam is Dim Check optical system and clean excess dust grime Also ensure that the 220V 110V switch is in the correct position if applicable No Light Output Check to ensure fixture is operating under correct ...

Страница 18: ...l 3 pin mic cables although this does not conform to the defined standard DMX is connected using a daisy chain configuration where the source connects to the input of the first device the output of the first device connects to the input of the next device and so on The standard allows for up to 32 devices on a single DMX link Each receiving device typically has a means for setting the starting cha...

Страница 19: ... wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a unit in for service But like any complex piece of equipment designed and built by humans once in a while something doesn t go as planned If you find yourself with a fixture that isn t behaving like a good little fi...

Страница 20: ...0 degrees C ambient Movement Range Pan 540 degree 8 16 Bit Resolution Tilt 280 degree 8 16 Bit Resolution Control Protocol USITT DMX 512 DMX Channels 21 23 28 channel DMX Modes Input 3 5 pin XLR Male Output 3 5 pin XLR Female Other Operating Modes Standalone Master Slave Auto Other Information The w in between really is Warranty 2 year limited warranty does not cover malfunction caused by damage t...

Страница 21: ...Page 21 Kryo Mix CMY User Manual Rev B c 2017 Blizzard Lighting LLC Dimensional Drawings 14 2 359 mm 22 7 579 mm 9 228 mm 13 1 333 mm 13 1 333 mm 14 2 359 mm ...

Страница 22: ...Page 22 Kryo Mix CMY User Manual Rev B c 2017 Blizzard Lighting LLC This page is intentionally left blank ...

Страница 23: ...Page 23 Kryo Mix CMY User Manual Rev B c 2017 Blizzard Lighting LLC This page is intentionally left blank ...

Страница 24: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting ...

Отзывы: