2
1.
Description and purpose of the stove:
BLIST solid fuel stoves are designed in a way to enable efficient combustion of solid fuels with the
possibility of adjusting and regulating the amount of input air required for the combustion process.
The stove consists of parts from steel, with doors and top plate made of cast iron or steel (depending
on the model of the stove), and the grate in the combustion chamber made of cast iron. All stoves are
plated inside with schamotte bricks, which provides long-term heat accumulation. The stoves are
painted with special heat resistant paint. The glass on the door is the first class heat resistant ceramic
glass.
The stoves are designed for space heating of a wide spectrum such as living rooms, offices, restaurants,
schools, garages, warehouses, etc. ..
- Models: KONZUL, KONZUL LM, AMBASADOR, AMBASADOR LM , DIPLOMAT LUX,
AMBASADOR R and AMBASADOR LM R have sides coated with ceramic tiles which gives unique
atmosphere to your room.
- Models: BLIST BR, BLIST BRM, AMBASADOR R and AMBASADOR LM R have oven with
built-in thermometer. Thus, alongside with heating of space, these stove models can be used for
baking also (of different kind of bread, pies, meat, etc..)
2. Installation:
- all local regulations including those refering to national and European standards needs to be complied
with when installing the appliance.
- Place of installation must be horizontal and must have adequate carrying capacity, otherwise must
be taken appropriate actions to fulfill these conditions.
- the stove must not be placed near combustible materials (such as wooden, textile or plastic furniture
parts, etc..) nor near cooling devices. Minimum distance between the stove and such materials must be
provided according to data from Table 1.
- if the stove is placed on the floor made from combustible materials (wood, itison, floor plastic, etc.)
it is necessary to protect the floor with metal sheet of min.30cm width from the sides of the stove, and
min. 50cm from the front side of the stove. Flue pipes must be away from combustible objects min.
40cm.
- When connecting the stove to the chimney you should consult a local competent institution. The
stove should be attached to a chimney with inner radius of at least 120mm and height of 6m. If multiple
stoves are attached to a single chimney, the attachment distance should be at least 2m. The chimney
should extend beyond the top of the roof min. 50cm. You should also pay attention that connection pipe
to the chimney does not stand out in the cross-section of the chimney, as well as the connection point of
flue pipe to the chimney must be tightly sealed. (see the Figure No.1) If two chimneys are going
parallel one to each other, they must have separate openings for cleaning, and cavities between the
chimneys also may not exist. Opening for cleaning the chimney must be tightly closed and sealed when
using the stove (while the fire runs in the stove). ). If the chimney is a newly built the fireplace must
not be constantly fired at full capacity until the chimney is completely dry.
- on the place of installation of the stove there must be provided free access for cleaning of the stove,
the flue connectors and the chimney itself.
- In order that stove work properly the necessary flue draught must be 12
÷
14 Pa. Check of the airflow
can be carried out by using a candle also, as shown in Figure no. 2