9/31
PowerTrackCANopenUM_REV1.4
15.
Object 1008h: Manufacturer Device Name
Identifier
615h (600h + current CAN ID)
Byte 0
40h
Read Device Register
Byte 1
08h
CAN Object 1008h
Byte 2
10h
Byte 3, 7
00h
Non used
Odd additional byte
Identifier
615h (600h + current CAN ID)
Byte 0
60h
Read Device Register Next Byte
Byte 1, 7
00h
Not used
Even additional byte
Identifier
615h (600h + current CAN ID)
Byte 0
70h
Read Device Register Next Byte
Byte 1, 7
00h
Not used
Examples:
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
40 08 10 00 00 00 00 00
Keypad Reply
595
Std
41 08 10 00 19 00 00 00
To Keypad
615
Std
60 00 00 00 00 00 00 00
Keypad Reply
595
Std
00 50 6F 77 65 72 54 72
PowerTr
To Keypad
615
Std
70 00 00 00 00 00 00 00
Keypad Reply
595
Std
10 61 63 6B 20 2D 20 42
ack - B
To Keypad
615
Std
60 00 00 00 00 00 00 00
Keypad Reply
595
Std
00 6C 69 6E 6B 20 4D 61
link Ma
To Keypad
615
Std
70 00 00 00 00 00 00 00
Keypad Reply
595
Std
17 72 69 6E 65 00 00 00
rine
Manufacturer Device Name: PowerTrack – Blink Marine