PowerTrackCANopenUM_REV1.4
28/31
31.
Object 2010h: Baud rate setting
Identifier
615h (600h + current CAN ID)
Byte 0
2Fh
Set Device Register
Byte 1
10h
CAN Object 2010h
Byte 2
20h
Byte 3
00h
Sub index
Byte 4
00h
1000k
01h
Reserved (force to 125k)
02h
500k
03h
250K
04h
125k (Default)
05h
Reserved (force to 125k)
06h
50k
07h
20k
Byte 5,7
00h
Not used
Example:
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
2F 10 20 00 03 00 00 00
Set baud rate = 250k
Keypad Reply
595
Std
60 10 20 00 00 00 00 00
32.
Object 2011h :Set Boot-up service
Object 2011h message enable or disable the boot up message sent by the keypad at power up to
the CAN network.
Identifier
600h + current CAN ID
Default 615h
Byte 0
2Fh
Set Device Register
Byte 1
11h
CAN Object 2011h
Byte 2
20h
Byte 3
00h
Sub index
Byte 4
XXh
00h: Not active
01h: Active
Byte 5,7
00h
Not used
Example:
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
2F 11 20 00 00 00 00 00
Set Boot-up service not
active
Keypad Reply
595
Std
60 11 20 00 00 00 00 00