Via Montefeltro, 6 – 20156 Milano (MI) – Italy
- 7 -
Tel. +39 (02) 3088583 – Fax +39 (02) 33406697
www.blinkmarine.com
–
PK-1400_J1939_UM_REV1.2
Set LED brightness level (02h)
This message sets the value of the indicator LED brightness. The value can be set from 0 to 3Fh
from a minimum value to 100% of the LED dimming range.
Byte 0
04h
Header bytes
Byte 1
1Bh
Byte 2
02h
LED brightness level message
Byte 3
XXh
XX: Dim Value (default 3Fh)
From 00h (min) to 3Fh (100%)
Byte 4,7
FFh
Not used
Example:
Direction
Identifier
Format
Message
Data
To keypad
18EF2100h Ext
04 1B 02 20 FF FF FF FF
Brightness set to 50%
8.
Set backlight level (03h)
This message sets the value of the backlight LED brightness. The value can be set from 0
to 3Fh for 0 to 100% of the brightness range.
Byte 0
04h
Header bytes
Byte 1
1Bh
Byte 2
03h
Backlight brightness level message
Byte 3
XXh
XX: Value (default 00h)
From 00h (0%) to 3Fh (100%)
Byte 4,7
FFh
Not used
Example:
Direction
Identifier
Format
Message
Data
To keypad
18EF2100h Ext
04 1B 03 10 FF FF FF FF
Backlight set to 25%
9.
Set startup keys message(28h)
This command enables the transmission during power up of the state of the keys.
Byte 0
04h
Header bytes
Byte 1
1Bh
Byte 2
28h
Startup keys message
Byte 3
XXh
XX:
00h Disabled (default)
01h Enabled
Byte 4,7
FFh
Not used
Example:
Direction
Identifier
Format
Message
Data
To keypad
18EF2100h Ext
04 1B 28 01 FF FF FF FF
Enable startup keys
message