PKP3500SI_CANopenUM_REV1.0
16/38
20.
Object 2010h: Baud rate setting
Set message:
Identifier
615h (600h + current CAN ID)
Byte 0
2Fh
Set Device Register
Byte 1
10h
CAN Object 2010h
Byte 2
20h
Byte 3
00h
Sub index
Byte 4
00h
1000k
01h
Reserved (force to 125k)
02h
500k
03h
250k
04h
125k (Default)
05h
Reserved (force to 125k)
06h
50k
07h
20k
Byte 5,7
00h
Not used
Read message:
Identifier
615h (600h + current CAN ID)
Byte 0
40h
Read Device Register
Byte 1
10h
CAN Object 2010h
Byte 2
20h
Byte 3
00h
Sub index
Byte 4,7
00h
Not used
Example:
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
2F 10 20 00 02 00 00 00
Baud rate = 500k
Keypad reply
595
Std
60 10 20 00 00 00 00 00
Command accepted
To Keypad
615
Std
40 10 20 00 00 00 00 00
Read command set
Keypad reply
595
Std
4F 10 20 00 02 00 00 00
Baud rate = 500k