TROUBLE SHOOTING (Cont'd.) 

TROUBLE 

CAUSE 

REMEDY 

A-6  
Leaks in urn body other than 
at fittings.

 

A-6

 

Pin holes or cracking of metal 
due to insulation action of lime 
or other abuse of urn.

 

A-6

 

Body leaks are best repaired at the factory. If soldering is attempted 
in the field, metal must be thoroughly cleaned. Use only a flux made 
specially for stainless steel and then neutralize completely. DO NOT 
WELD OR BRAZE ! ! !

 

A-7  
Water leaks or sprays out 
through top of urn.

 

A-7.1

 

Water compartment overfilled through 
oversight or because of leaky water 
inlet valve.

 

A-7.1  
Draw off excess water from water compartment by opening hot 
water faucet. Never fill to a level higher than uppermost mark on 
water gauge glass. Water expands with heat and can cause an 
overfilled condition. To check whether overflowing is due to leaking 
water inlet valve, proceed as follows: Shut off heating unit to urn. 
(Check cannot be made accurately if water is boiling.) Close water 
inlet valve firmly and note accurately water level in gauge glass. If 
water level rises after a period of time, a leaky water inlet valve is 
indicated. Remove valve bonnet, unscrew stem and install new 
valve disc.

 

 
 

A-7.2

 

Excessive heat is applied to urn. This 
is a rare cause, and is usually due to 
excessive steam pressure in steam 
heated urns, or an improperly 
adjusted electric thermostat in 
electrically heated urns.

 

A-7.2

 

If steam pressure is considerably in excess of that for 
which urn was ordered, install reducing valve to cut 
pressure down to that recommended for urn. Or, control 
heat, input by fuel control valve. On electric urns, adjust 
thermostat as shown on page 5.

 

B FILTERING AND BREWING 

B-1

 

Filtering through Tri-Saver 
is slow.

 

B-1. 1

 

Too fine grind prevents normal filtration.

 

B-1. 1  
Have coffee supplier match sample grind packed with Tri-Saver 
filter. If sample is lost, write factory for another.

 

 
 

B-1. 2  
Filter clogged because not cleaned 
regularly and according to instructions. 
Extenders in coffee may also cause 
clogging.

 

B-1. 2  
Follow instructions on plate attached to Tri-Saver filter, or see page 
8. Clogged filter can be cleaned by soaking overnight or several 
nights in water with a good detergent. Avoid using coffees with 
extenders as it may not be possible to dean these out.

 

10 LSQ

 

B-1. 3  
Soft water used.

 

B-1. 3  
Water may be "conditioned" but not softened. Slows up leeching 
and destroys coffee taste.

 

 

Содержание LSQ 600 series

Страница 1: ...ached to urn An experienced electrician should make the installation and he should check that the proper size power cable leads to your urn and that the circuit is fused adequately Do notsupply power to a dry urn GAS CONNECTIONS Connect 1 2 gas supply Burner is rated at 22 000 BTU on twin LSQ urn and 15 000 BTU on single LSQ urn Do not apply heat to a dry urn STEAM CONNECTIONS On steam heated urns...

Страница 2: ... 9 14 The purpose of this manual is to help you keep your urn in perfect operating condition It should be studied carefully at time of installation and kept for future reference Proper care in operation and maintenance will protect your investment and assure a uniformly delicious brew Additional copies of this book are available at 1 00 each If any problems arise which are not covered in this manu...

Страница 3: ...rate inefficiently ELECTRIC Electrically heated units normally furnished with thermostat pre set at Factory No 10 position is 210 and decreases according to position you leave thermostat set at CAUTIONS a If steam is used for heating pressure should be approximately 20 25 Ibs Do not use a different pressure unless your urn was ordered for it b Never allow water level in boiler gauge to go lower th...

Страница 4: ... gallon or so of fresh water in the liner Do not drain this water off until just before making next coffee brew 6 After removing grounds take a gallon measurer and pour brewed coffee over to blend the coffee TWICE A WEEK Coffee urns must have a special scouring twice a week To scour the urn thoroughly 1 Be sure water jacket is 3 4 full of water and turn on heat 7 Allow 10 minutes for fresh coffee ...

Страница 5: ...rn control to off position and remove black knob 2 With a small screwdriver turn screw A clockwise to decrease and counter clockwise to increase the temperature 3 Adjusting the calibration screw 1 4 turn will increase or decrease the temperature approximately 10 F 4 Replace knob and turn thermostat back to the No 10 position and check to see if it is calibrated properly When the thermostat is in t...

Страница 6: ...omptly whenever thermostatic action appears defective CLEAN VALVE DISC AND SEAT EVERY 60 DAYS After several hours use on a new installation and every 60 days thereafter Valve disc gland pin and seat should be cleaned to insure proper operation Proceed as follows TO CHECK CLEAN STRAINER If there is a noticeable increase in time required to heat urn this may be due to clogging of the strainer on the...

Страница 7: ...burner flame turn screw under GAS COCK HANDLE in either direction to regulate flow of gas to main burner To Recalibrate Thermostat a Allow heater to set without the burner on for at least30 minutes to allow the water temperature within the tank to reach its equilibrium point b Turn the DIAL ASSEMBLY until the main burner ignites c Slowly turn the DIAL ASSEMBLY until the main burner is extinguished...

Страница 8: ...ne teaspoonful of any good free rinsing detergent per gallon and submerge the filter Push the filter in an upward and downward motion so that the water will flow through the filter plates cleaning them thoroughly Daily care will keep your filter clean and will assure perfect coffee flavor IF FOR ANY REASON YOUR TRI SAVER FILTER DOES NOT GIVE YOU VERY SATISFACTORY RESULTS COMMUNICATE WITH US OR YOU...

Страница 9: ...g nut depending on where leak occurs If leak continues replace gauge glass washers Unscrew upper fittings Remove old washers and slip new ones in at each end Replace glass and tighten nuts A 3 Faucet Drips A 3 Tomlinson inserts are worn and must be replaced A 3 Disassemble faucet and replace insert A 4 Fittings leak at body of urn A 4 1 Jam nut is loose A 4 1 Tighten jam nut If this does not stop ...

Страница 10: ...ve is indicated Remove valve bonnet unscrew stem and install new valve disc A 7 2 Excessive heat is applied to urn This is a rare cause and is usually due to excessive steam pressure in steam heated urns or an improperly adjusted electric thermostat in electrically heated urns A 7 2 If steam pressure is considerably in excess of that for which urn was ordered install reducing valve to cut pressure...

Страница 11: ...plier match grind sample furnished with urn B 4 2 Tri Saver filter is damaged permitting water to pass through through too quickly for full flavor extraction B 4 2 Examine filter for dents or damage due to abuse If damaged return to factory for repair B 4 3 Incorrect proportion of water to coffee B 4 3 See B 2 above B 4 4 Water not at proper temperature B 4 4 Do not brew coffee unless water is at ...

Страница 12: ...ther point in the building or that fuse in line is not blown D 1 2 Thermostat may be out of adjustment D 1 2 To check this and adjust thermostat see instructions on page 5 D 1 3 Lime deposits insulate heating elements preventing heat from being transferred to water D 1 3 Clean out urn Hard lime deposits may require factory cleaning Install water conditioner to prevent lime deposit 12LSQ D 1 4 Heat...

Страница 13: ...ow of water completely because of faulty washer E 2 2 Shut off main water valve in line immediately before urn Remove valve bonnet unscrew valve stem and replace valve disc E 3 Water in urn jacket gauge is discolored with coffee E 3 1 Urn liner has been overfilled allowing some coffee to seep into urn jacket E 3 1 Drain jacket water and replace with fresh water Avoid overfilling liner E 3 2 Leak a...

Страница 14: ...n page 7 F 2 Gas does not shut off F 2 1 Manual by pass gas cock is open F 2 1 Close this gas cock This gas cock should only be opened in the event of a power failure You may then use this to feed gas to the burners manually until power is restored F 2 2 Thermostat is set too high F 2 2 To check this and adjust thermostat see instructions on page 7 F 3 Gas flame floating F 3 1 Gas orifice and air ...

Страница 15: ...chase Also give catalog number and size of urn The serial number will be found stamped in the upper part of the urn body at the right side as you face the urn or on data plate of electric urns A minimum charge of 15 00 will be made on all orders for spare parts when placed through factory Blickman Equipment Corporation 2017 KERRIGAN AVENUE UNION CITY N J 07087 201 867 8100 15LSQ ...

Страница 16: ...D LOWER FERRULE LSQ 122 22770 GAUGE SHIELD ASSM 10 W CAP FER LSQ 123 22810 GAUGE SHIELD ASSM 16 W CAP FER LSQ 124 22830 GAUGE SHIELD ASSM 19 W CAP FER LSQ 125 GAUGE GLASS 3 GAL 9 15 16 LSQ 126 GAUGE GLASS 6 GAL 15 15 16 LSQ 127 GAUGE GLASS 10 GAL 18 15 16 MINI BREW LSQ 128L 22910 GAUGE GLASS WASHERS LOWER DZ LSQ 128U 22900 GAUGE GLASS WASHERS UPPER DZ LSQ 129 22170 FAUCET TYPE ES TOMLINSON BLACK L...

Отзывы: