Tips for success:

•  Do not skip the pH measurements! If your mash is much above the recommended pH you risk astringency in your 

beer among other detrimental changes. Adding water salts and acid may be necessary to achieve proper pH in 

any all-grain brewing system.

•  During dough-in, an occasional gentle stirring will break up any clumps and release air pockets. The dough-in 

process is vital for problem free recirculation.

•  Let the grain sit (dough-in) for about 10 min to absorb the liquor and for the air to purge out of the grain. 

•  Consult the two recommended books, How to Brew and Water by John Palmer and Colin Kaminski (published by 

the Brewers Association) to learn how to properly adjust your mash pH and to educate yourself on good brewing 

practices.

•  Measure the specific gravity periodically. The SG of the mash is the same as the pre-boil wort SG. Make adjust-

ments to your wort such as adding malt extract, water, or mashing longer to achieve the desired SG of the pre-boil 

wort

Tip:

 As with any new system it will take a few batches to dial in your efficiency and water usage requirements. Always 

make careful notes, and closely follow recommendations found in this manual.  If you are new to all grain brewing we 

suggest reading John Palmer’s book “

How to Brew”

, published by the Brewers Association before your first batch.  This 

manual is not intended to be a complete all-grain brewing text.

IMPORTANT: 

The quality of your finished beer will be directly related to the quality of your brewing water. If you have 

especially hard water in your area, it is strongly recommended that you dilute your tap water with distilled or reverse 

osmosis water or build your brewing water from scratch. For optimum results, the mash pH must fall within a range 

of 5.2 – 5.6 at room temperature. Additionally, a minimum of 100 ppm of Ca is required. For more information, further 

reading is recommended, specifically John Palmer & Colin Kaminski’s book “

Water

”, published by the Brewers 

Association.

IMPORTANT: 

 We highly recommend the purchase of a digital pH meter for monitoring pH.  Test strips, while 

inexpensive, do not provide adequate precision for brewing.  Despite many pH meters being automatic temperature 

correcting, pH levels change with temperature. If you are reading the meter at mash temperatures, the range for mash 

pH is between 5.1 and 5.4 pH. This will result in a room temperature pH at the recommended range of 5.2-5.6 pH.

Cleaning Procedures

Cleaning of the BrewEasy™ Compact system is very straight-forward. Clean any components that will contact the

liquid, wort, or other brewing ingredients with a mild detergent (non- chlorine) or Powdered Brewery Wash (PBW)

before your first use and after every subsequent use. Soak the hoses in a PBW solution, rinse with hot tap water and 

soak in a non-chlorine sanitizer.

Содержание BrewEasy Compact NPT

Страница 1: ...act your retailer or Blichmann Engineering www BlichmannEngineering com before use Sections labeled Important should specifically be followed to ensure satisfactory results with the product WARNING CAUTION IMPORTANT IMPORTANTINFORMATION PLEASEREADANDTHOROUGHLYUNDERSTANDTHISMANUALPRIORTOUSE FORIMPORTANTSAFETYINFORMATION Brewing has inherent hazards and requires care focus and a mindset of safety an...

Страница 2: ...ctric 240V BrewCommander 1 Comes with 240V selection aBrewCommander 120V Electric 120V BrewCommander 1 Comes with 120V selection aBrewCommander Gas Gas BrewCommander 1 Optional with gas selection BMA 002F A Brewmometer F 1 Optional with gas selection Recirculation Kit Parts BE 001996 00 Sparge Tube Assembly 1 BE 500004 00 Sparge Tube Port Bulkhead 1 BE 000067 00 Retaining O ring 2 KTL 010 00 Retai...

Страница 3: ...e IMPORTANT If you are using the Blichmann HellFire Burner it comes configured for LP operation For use with natural gas you will need to install a natural gas conversion kit Step Two Next install the dip tube and drain valve on the front of your kettle To do so put the dip tube shaft collar fitting and the silicone white o ring into the bottom hole on the inside of the front of the kettle Then pl...

Страница 4: ...ad tape is required Kettle wall Step Three In the lower hole on the back of the left of the kettle install the temperature probe as shown in the exploded view below If you purchased your system without a controller install the included Brewmometer in the 1 2 hole in the front of the kettle TEMPERATURE SENSOR ASSEMBLY Number Part Number Description 1 BE 000882 01 Sanitary Nut 2 BE 000882 01 Sanitar...

Страница 5: ...We recommend that the straight barb QuickConnectors go on the hose that attaches to the drain valve and the pump inlet TIP On straight QuickConnectors leave approximately 1 8 of space between the QuickConnector nut and silicone hose before tightening the plastic clamp TIP Install the QuickConnectors is such a way that minimizes the potential for kinks that can restrict flow TIP Do not mount the pu...

Страница 6: ...tion of the mashing period Set the flow of the pump to 0 75 gallons per minute and monitor this flow by checking the flow meter throughout the mash If desired after starch conversion you can heat the mash to the desired mash out temperature using the same method described in the Mashing section of this manual Allow the mash to rest at the mash out temperature for an adequate amount of time to stop...

Страница 7: ...ing John Palmer s book How to Brew published by the Brewers Association before your first batch This manual is not intended to be a complete all grain brewing text IMPORTANT The quality of your finished beer will be directly related to the quality of your brewing water If you have especially hard water in your area it is strongly recommended that you dilute your tap water with distilled or reverse...

Страница 8: ...ty or any implied warranty of fitness is limited in duration to the terms of this limited warranty and is limited in scope of coverage to this warranty Blichmann Engineering disclaims any express or implied warranty including any implied warranty of fitness for a particular purpose or merchantability on items excluded from coverage as set forth in this limited warranty 2 Blichmann Engineering make...

Отзывы: