BoilerMaker™ V7
© Blichmann Engineering, LLC 2020
For replacement parts, visit: blichmannengineering.com/genuine-replacement-parts
2
We recommend that you clean the BoilerMaker™ and accessories thoroughly prior to use to remove any traces of manufacturing
residue including disassembling the valve.
Note:
The Heat Shield is not included with BoilerMarker™ electric Kettles with the BoilCoils™, nor is it required with electric heating
CAUTION:
As with all bimetal thermometers, excessive heat can damage
the seals, causing the dial face to fog. This failure is not covered under
warranty. An 8” x 3” stainless shield is provided to protect components
from heat. Screws are provided to attach the heat shield to your burner.
In all cases, always keep the flame low enough that it does not roll over
the edge of the kettle.
If you cannot hold your hand on the case of
the thermometer during operation it is too hot and you must reduce
the heat from the burner.
Lastly, avoid direct spray of water on the
thermometer and do not immerse for cooling and cleaning. Excessive
thermal shock can shatter the glass bezel.
Assemble BrewMometer
™
(
shown in Fig 1
) by tightening the nut snugly.
(20 ft-lb or 27 N-m) using wrenches on both sides of the kettle but do not use excessive force.
Do not use pipe tape on the threads.
Do not hold by the dial-face - use a wrench!
Use Wrenches on both sides of the pot do not tighten by holding the dial face of the thermometer or you will damage the
thermometer seals! NOTE that the O-ring and retainer go on the OUTSIDE of the kettle. Installing washer and O-ring on the inside of
the kettle will cause the kettle to leak.
Adjusting the BrewMometer™ Faceplate
The adjustable faceplate BrewMometer
™
(
shown in Fig. 2
) can be adjusted to virtually any convenient viewing angle. To change
the viewing angle, simply loosen the long screws and nuts and rotate the pivoting mechanism to the desired position (
shown in Fig.
3
) The move dial face to the desired viewing angle (
shown in Fig. 4
). If the pivoting mechanism is too stiff to easily move by hand,
loosen the screws on the picoting mechanism slightly to allow for the proper motion (
shown in Fig. 4
) Forcibly moving the mech-
anism may twist the bellows which is not covered under warranty. The temperature reading may shift when adjusting the viewing
angle, but this is a temporary phenomenon and will equalize quickly.
ASSEMBLY & INSTALLATION
Use of the BrewMometer™
Note:
The BrewMometer Manual
™
is included in the BrewMometer
™
Package. Please consult that manual for use and
installation.
Fig. 1
Fig. 2
Sanitary Nut
Screws
Pivoting Mechanism
Long Screws
and Nuts
Fig. 4
Fig. 3