TROUBLESHOOTING
PROBLEM: Too much heat.
CAUSE
By-Pass door left open.
SOLUTION
Close the by-pass door.
Thermostat set too high.
Lower thermostat setting.
Loading door gasket leaking, admitting excess air
into fi rebox.
Replace door gasket and/or adjust door. See “GASKET
INSPECTION”
Excessive draft in the chimney.
Measure draft with a Manometer. See “DRAFTS”. Consult your
Blaze King dealer or a chimney sweep. Install a cap.
Thermostat not operating properly.
Consult your Blaze King dealer.
Wood is too small.
Use larger pieces.
PROBLEM: Excessive creosote formation in chimney and chimney Connector.
CAUSE
By-pass door left open.
SOLUTION
Close by-pass door.
By-pass door not sealing tightly.
Inspect by-pass door and seal for warping. Ash or creosote
buildup may occur on door or seat. With stove cold scrape and
vacuum area around by-pass. Be sure all mating steel surfaces
are clean and smooth.
Improper operation.
Check thermostat setting and operating procedures. See
“THERMOSTAT & OPTIMAL THERMOSTAT SETTING”
Wood too green or wet.
Use seasoned wood. Use a moisture meter to confi rm.
Catalytic combustor not operating properly.
Inspect the combustor. See “CATALYTIC COMBUSTOR,
TESTING”
Poor draft caused by an oversize or short fl ue, etc. Measure draft with Manometer. See “DRAFTS”. Consult your
Blaze King dealer or a chimney sweep.
Chimney too cold or poorly insulated.
Upgrade chimney system. Consult your Blaze King dealer or a
chimney sweep.
PROBLEM: Catalytic combustor thermometer (on top of stove) does not go into "Active" zone, or does not stay
there for long.
CAUSE
Improper operation.
SOLUTION
Check thermostat setting and operating procedures. See
“THERMOSTAT & OPTIMAL THERMOSTAT SETTING”
Obstruction in chimney or cap.
Clean chimney, remove obstructions.
Faulty combustor thermometer.
Replace thermometer and Recheck combustor operating
Temperature.
Wood too green or wet.
Use seasoned wood.
PROBLEM: Spots of creosote accumulation in chimney or chimney connector.
CAUSE
Air leaks in chimney or chimney connector.
SOLUTION
Inspect chimney and / or chimney connector. Repair or replace
as necessary. Check to be sure that the chimney connector is
installed correctly.
CAUTION: a leaking chimney connector is a fi re hazard and demands immediate attention.
Poor draft caused by an oversize fl ue, single wall
pipe, to many elbows, etc.
Measure draft with Manometer. See “DRAFTS”. Consult your
Blaze King dealer or a chimney sweep.